Adjusting Settings in Configuration Mode
70
Freedom X 1200 Owner's Guide
Setting
(with default
values)
LCD
Screen
(Left
Side)
LCD
Screen
(Right
Side)
Range of values
Description
Transfer Mode
07
aPL
APL
This default setting is for typical household appliances. It
allows the transfer of shore power (AC MODE) to the loads
from battery power (Batt. MODE) within 20 milliseconds and
vice versa.
UPS
This faster setting is for sensitive digital equipment like desktop
computers. The transfer time is similar to a UPS in which it
allows the transfer of shore power (AC MODE) to the loads
from battery power (Batt. MODE) within 10 milliseconds and
vice versa.
Output Frequency
08
60
60 Hz
This default AC output frequency setting of 60 Hz is commonly
used in North American jurisdictions.
50 Hz
This AC output frequency setting of 50 Hz is used in
jurisdictions such as in some Latin American countries
operating from 115 VAC/50 Hz. If the utility and inverter are set
to 50 Hz, load appliances must also be rated to operate from
115 VAC/50 Hz power.