Basic Installation Procedures
975-0767-01-01
31
Disconnect
Devices
Each system requires a method of disconnecting
the AC circuits. If the over-current protection
devices are circuit breakers, they will also serve as
the disconnects. If fuses are used, separate AC
disconnect switches will be needed ahead of the
fuses. These will have to be a branch circuit rated
for 120 volts AC and have an appropriate current
rating.
AC Distribution Panels
Most systems incorporate distribution centers both ahead of the
Freedom X 1200 (the AC source panel) and between the Freedom
X 1200 and the loads (the AC load panel). An AC source panel
includes a main circuit breaker, which serves as over-current
protection and as a disconnect for the AC shore power supply line.
Additional circuit breakers serve individual circuits, one of which
serves the Freedom X 1200. The AC load panel can incorporate
an AC output circuit breaker and breakers for individual load
circuits.
NOTICE
RISK OF INVERTER DAMAGE
Do not connect the Freedom X 1200 to a 120/240V, 3-pole, 4-
wire circuit.
Failure to follow these instructions can result in equipment
damage.
AC Cabling
AC cabling includes all the wires and connectors between the AC
source and the Freedom X 1200, as well as all AC cabling
between the Freedom X 1200 and the AC output panels, circuit
breakers, and loads. The type and size of the wiring varies with
the installation and load. For example, in high vibration
environments, such as marine or RV applications, wire nuts may
not be acceptable, so crimp splices would be required. In other
Содержание Freedom X 1200