Basic Installation Procedures
50
Freedom X 1200 Owner's Guide
Match the wire connectors to the corresponding terminals:
1. Connect each AC wire into its corresponding terminal on the
no-tool cage clamp terminal block by lifting the terminal
lever, insert the ferrule fully into the open slot, and lowering
the terminal lever to secure the wire in the slot.
a. Connect
1b
to
9
.
b. Connect
2d
to
10
.
c. Connect
3d
to
11
.
Make sure that each AC wire is matched and connected to
the Line (
L
), Ground (
G
), and Neutral (
N
) connections.
2. Route the AC cable as shown in
item 14 and strip
each of the wires
14a, 14b, 14c
within the unit.
3. Splice the following using a twist-on wire connector as
shown in
.
a. Splice
1a, 4b,
and
14a.
b. Splice
2b, 2c,
and
14b.
c. Splice
3b, 3c,
and
14c.
4. Connect
2a
to
8
.
5. Connect
3a
to
6
.
6. Connect
4a
to
7
.
7. Attach and secure the GFCI receptacle to the panel inside
the wiring compartment using the two mounting screws as
shown in
item 12.
Figure 14 Wiring diagram
L G
AC OUT
N
N G
AC IN
L
12. Tighten the strain relief clamp to secure the wires.
13. Replace the wiring compartment cover (using a #2 Phillips
torque screwdriver - see WARNING), if you are finished with
connecting all the AC wires in the unit.