Basic Installation Procedures
54
Freedom X 1200 Owner's Guide
WARNING
ELECTRICAL SHOCK HAZARD
n
Tighten the nuts on the DC terminals properly. Loose
connections cause excessive voltage drop and may
cause overheated wires and melted insulation.
n
Do not over-tighten the nut on the DC input terminals
because damage to the DC input terminals may result.
Use a torque screwdriver to tighten the nut to a maximum
torque of 80 in-lb (9 N-m) of force.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
NOTICE
REVERSE POLARITY
n
Check cable polarity at both the battery and the Freedom
X 1200 before making the final DC connection. Positive
must be connected to positive; negative must be
connected to negative. Check to see if the reverse polarity
LED (see
Step 6: Connecting the DC Cables
) is not
illuminated.
n
Reversing the positive and negative battery cables will
blow a fuse in the Freedom X 1200 and void your
warranty.
Failure to follow these instructions can result in equipment
damage.
Figure 16 DC Cable Connections
1
2
3
4
5
7
6
1
DC terminal bolt nut
2
lock washer
3
flat washer
4
cable ring lug
5
DC terminal
6
DC knockout hole
7
DC cable with heat shrink insulation covering the lug stem
NOTE
: The DC cable lug stem must be fully insulated with the heat shrink.
12. Before proceeding, double check that the cable you have
just installed connects the positive DC terminal of the
inverter to the disconnect/battery selector switch, fuse
holder, and that the other end of the fuse holder is connected
to the positive terminal of the battery.