background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

PROFINET / DeviceNet Slave  

 

 

Document code: MN67609_ENG     Revision 1.001   Pagina 1 di 22

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
                                                                                          
 
 
 
 
 
 
 
 

User Manual 

Revision 1.001 
English 

 

PROFINET / DeviceNet Slave - 
Converter 

 (Order Code:  HD67609-A1) 

 
for Website information:  

www.adfweb.com?Product=HD67609

 

 

for Price information: 

www.adfweb.com?Price=HD67609-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Two PROFINET ports 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

 

For others PROFINET products see also the following link: 

 

Converter PROFINET to  

www.adfweb.com?Product=HD67606

      

(CAN)

 

www.adfweb.com?Product=HD67608

      

(DeviceNet Master) 

www.adfweb.com?Product=HD67610

      

(J1939)

 

www.adfweb.com?Product=HD67600

      

(NMEA2000)

 

www.adfweb.com?Product=HD67601

      

(Serial RS232)

 

www.adfweb.com?Product=HD67601

      

(Serial RS485)

 

www.adfweb.com?Product=HD67602

      

(Modbus Master RS232)

 

www.adfweb.com?Product=HD67602

      

(Modbus Master RS485)

 

www.adfweb.com?Product=HD67603

      

(Modbus Slave RS232)

 

www.adfweb.com?Product=HD67603

      

(Modbus Slave RS485) 

www.adfweb.com?Product=HD67604

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67605

      

(PROFIBUS Slave) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

Other 
Products 

Axis Solutions Pvt Ltd is the Authorized Distributor of 

$')ZHE

 in India  

www.axisindia.in | [email protected]

Axis Solutions Pvt Ltd is the Authorized Distributor of 

$')ZHE

 in India  

www.axisindia.in | [email protected]

Axis Solutions Pvt Ltd is the Authorized Distributor of 

$')ZHE

 in India  

www.axisindia.in | [email protected]

Axis Solutions Pvt Ltd is the Authorized Distributor of 

$')ZHE

 in India  

www.axisindia.in | [email protected]

Summary of Contents for HD67609-A1

Page 1: ...MEA2000 www adfweb com Product HD67601 Serial RS232 www adfweb com Product HD67601 Serial RS485 www adfweb com Product HD67602 Modbus Master RS232 www adfweb com Product HD67602 Modbus Master RS485 ww...

Page 2: ...that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top right hand cor...

Page 3: ...hanical interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the i...

Page 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET DeviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 4 di 22 EXAMPLE O...

Page 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET DeviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 5 di 22 CONNECTION SCHEME Figure 1 C...

Page 6: ...455 bytes in reading and 455 bytes in writing Triple isolation between DeviceNet Power Supply DeviceNet Ethernet Power Supply Ethernet Two directional information between DeviceNet bus and PROFINET b...

Page 7: ...eviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 7 di 22 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmi...

Page 8: ...he Dip2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for upload the Proj...

Page 9: ...ate Blinks very slowly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times...

Page 10: ...FINET connection must be made using Connector3 and or Connector4 of HD67609 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the...

Page 11: ...Document code MN67609_ENG Revision 1 001 Pagina 11 di 22 DeviceNet For terminate the DeviceNet line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteri...

Page 12: ...S 2000 XP Vista Seven 8 32 64bit When launching the SW67609 the right window appears Fig 2 Note It is necessary to have installed Net Framework 4 NEW PROJECT OPEN PROJECT The New Project button create...

Page 13: ...r In the fields SUBNET Mask insert the SubNet Mask In the fields GATEWAY insert the default gateway that you want to use This feature can be enabled or disabled pressing the Check Box field This featu...

Page 14: ...ctual IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Pres...

Page 15: ...n the device is correctly update Note When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67609 A1 device Note When you receive the...

Page 16: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET DeviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 16 di 22 MECHANICAL DIMENSIONS Figure 10 Mec...

Page 17: ...ng part number is formed by a valid combination of the following HD67609 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67609 PROFINET De...

Page 18: ...001 Pagina 18 di 22 PLC CONFIGURATION The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11 software of...

Page 19: ...eviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET DeviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 19 di 22 2 Import the module in the network connect the device to...

Page 20: ...Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET DeviceNet Slave Document code MN67609_ENG Revision 1 001 Pagina 20 di 22 3 Load the confi...

Page 21: ...uropean countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an a...

Page 22: ...th the request you need to provide detailed information about the problem 2 Send the product to the address provided with the PRN having prepaid the shipping costs shipment costs billed to us will not...

Reviews: