Basic Installation Procedures
44
Freedom X 1200 Owner's Guide
WARNING
ELECTRIC SHOCK HAZARD
Use a screwdriver to loosen the captive nut panel screw.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
4. Strip a single AC output wire, as appropriate. Strip 15 mm off
the ends of each of the three the wires (tin the exposed
copper wire with lead-free solder using a soldering iron).
5. Remove the knockout and install a ½" strain relief clamp.
6. Route the wires through the strain relief clamp (not shown in
the figure).
7. Connect each AC wire into its corresponding terminal on the
no-tool cage clamp terminal block.
a. Lift the terminal lever (as shown on the figure).
b. Insert the wire fully into the open slot.
c. Lower the terminal lever to secure the wire in the slot.
8. Make sure that each AC wire is matched and connected to
the Line (
L
), Ground (
G
), and Neutral (
N
) connections.
9. Tighten the strain relief clamp to secure the wires.
10. Replace the wiring compartment cover (using a #2 Phillips
torque screwdriver - see WARNING), if you are finished with
connecting all the AC wires in the unit.
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
5 in-lb (0.56 N-m) torque of force to ensure a proper ground
connection and a required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
11. Connect the other end of the wires to a circuit breaker in AC
distribution panel providing AC power to the loads.
12. End of
.