background image

Deutsch

English

Français

IZAR CENTER

Einbauanleitung 

Installation guide

Guide d’installation

Diese 

Anleitung ist 

dem Endkunden 

auszuhändigen.  

This guide must 

be given to the end 

consumer.  

Ce guide doit être 

donné au client 

final.

1   2   3   4   5   6

29 30 31 32  33  34

IZAR

CENTER 250

M e m o r y

M-Bus 

USB/LAN 

RS232/Rep 

Modem 

Rx/Tx 

Summary of Contents for Izar Center

Page 1: ...allation guide Guide d installation Diese Anleitung ist dem Endkunden auszuhändigen This guide must be given to the end consumer Ce guide doit être donné au client final 1 2 3 4 5 6 29 30 31 32 33 34 IZAR CENTER 250 Memory M Bus USB LAN RS232 Rep Modem Rx Tx ...

Page 2: ...ENTER 250 Memory 1 2 3 4 5 6 29 30 31 32 33 34 IZAR CENTER 250 Memory M Bus USB LAN RS232 Rep Modem Rx Tx 1 2 3 4 5 6 29 30 31 32 33 34 IZAR CENTER 250 Memory M Bus USB LAN RS232 Rep Modem Rx Tx 1 2 3 4 5 6 29 30 31 32 33 34 IZAR CENTER 250 Memory M Bus USB LAN RS232 Rep Modem Rx Tx PC USB LAN RS232 Modem PC USB LAN RS232 I II ...

Page 3: ...TER schickt eine Anfrage an die am M Bus angeschlossenen Zähler Diese Aktion kann manuell durch den Benutzer oder automatisch durch den IZAR CENTER ausgeführt werden Zur automatischen Zählerauslesung wird ein IZAR CENTER mit Memory benötigt in den ein allgemeines oder zäh lerindividuelles Ausleseintervall programmiert wird Der Zähler antwortet auf diese Anfrage indem er seine aktu ellen Werte an d...

Page 4: ...enprofil aus wärmebeständigem Kunststoff ABS Schutzklasse IP 20 Schnittstellen USB Ethernet LAN RS232 für PC Modem M Bus Ausgang und M Bus Repea ter Eingang M Bus Übertragungsraten 300 600 1200 2400 4800 9600 Baud Autobaud Erkennung über RS232 Betriebstemperatur 20 C 70 C Luftfeuchtigkeit 10 90 relative Luft feuchtigkeit nicht konden sierend Gewicht ca 472 g ...

Page 5: ...chließlich beim Verursacher Der IZAR CENTER darf nur von Fachkräften montiert und in Betrieb genommen werden 6 Montage Demontage Vor jeder Montage oder Demontage muss die Stromzuführung Buchse 16 Abb I unterbro chen werden IZAR CENTER montieren Schnappen Sie den IZAR CENTER auf die Hutschi ene auf Der schwarze Sicherungsbügel Buchse 65 Abb I muss dabei nach unten zeigen und hörbar einrasten IZAR C...

Page 6: ...nes Blitzschutzes erforderlich Folgende Typen sind hierfür qualifiziert M Bus Verbindungen Dehn BXT und Dehn Modul BXT ML2 BD S48 Diehl Metering Art Nr 3055664 LAN Verbindungen Dehn DPA M CAT6 RJ45 S48 Diehl Metering Art Nr 3055635 Die Stromversorgung muss nicht unterbrochen werden um M Bus Geräte am IZAR CENTER anzuschließen Klemme Buchse Beschreibung 1 M Bus Repeater Eingang 2 M Bus Repeater Ein...

Page 7: ...e 68 Stecker für LAN Anschluss M Bus Zähler Anschluss über die M Bus Ausgangsklemmen Der M Bus ist polaritätsunabhängig es muss nur jeweils ein und ein Ausgang mit dem entsprechenden M Bus Zähler verbunden werden Alle M Bus Ausgänge sind par allel geschaltet Repeater M Bus Ausgang eines weiteren IZAR CENTERs an die Klemmen 1 und 2 anschließen Verbinden Sie die Klemme 5 oder 6 mit einen Schutzerdep...

Page 8: ...n Betriebszustände an M Bus Anzeige Betriebszustand grün 0 100 Buslast gelb 100 130 Buslast Warnung Die maximale M Bus Leistung ist erreicht Schließen sie keine weiteren M Bus Zähler mehr an In diesem Zustand ist der IZAR CENTER noch voll funktionsfähig rot Überlast In diesem Fall sind entweder zu viele M Bus Zähler angeschlossen oder die Busleitun gen haben einen Kurzschluss Bei Busüberlast wird ...

Page 9: ...n empfangen Gelb Daten werden gesendet 9 Wartung Der IZAR CENTER benötigt keine besondere Wartung Nicht mit Lösungsmitteln oder Scheuermittel reinigen da diese das Kunststoffgehäuse beschädigen können Wenn nötig Tuch oder feuchten Schwamm zur Reinigung verwenden 10 Lagerung Der IZAR CENTER kann an einem trockenen Ort bei Tem peraturen zwischen 20 C und 70 C gelagert werden 11 Umwelthinweis Das Ger...

Page 10: ... CENTER der Richtlinie 2014 53 EU entspricht Der vollständige Text der EU Konformitätserklärung ist unter der folgenden Internetadresse verfügbar http www diehl com de diehl metering produkte loesungen produkt download Bitte wählen Sie dort den Partner Diehl Metering GmbH und den Produktbereich Systemtechnik aus ...

Page 11: ...able 3 Description The IZAR CENTER sends a request to the meters con nected to the M Bus This action can be performed man ually by the user or automatically by the IZAR CENTER For the automatic meter reading a IZAR CENTER with memory is required where a general or meter individ ual reading interval is programmed The meter responds to this request by sending the current values to the IZAR CENTER Th...

Page 12: ...breaker profile from heat resistant plastic ABS Protection class IP 20 Interface USB Ethernet LAN RS232 for PC modem M Bus output and M Bus Repeater input M Bus transmission rate 300 600 1200 2400 4800 9600 baud autobaud detection via RS232 Operating temperature 20 C 70 C Relative humidity 10 90 relative humidity non condensing Weight approx 472g ...

Page 13: ...ng In this case the responsibility lies solely with the originator The IZAR CENTER should be mounted and put into operation by qualified experts only 6 Installation removal Before every installation or removal the power supply socket 16 fig I must be interrupted Install IZAR CENTER Snap the IZAR CENTER onto the hat rail The black safety catch socket 65 fig I must point downwards and engage audibly...

Page 14: ...ning protection is required The following types are qualified for this purpose M Bus connections Dehn BXT and Dehn module BXT ML2 BD S48 Diehl Metering art no 3055664 LAN connections Dehn DPA M CAT6 RJ45 S48 Diehl Metering art no 3055635 The power supply must not be interrupted to connect M Bus devices to IZAR CENTER Terminal socket Description 1 M Bus repeater input 2 M Bus repeater input 5 6 Pro...

Page 15: ...S232 interface 68 Plug for LAN connection M Bus meter Connection via the M Bus output terminal The M Bus is not polarity conscious a and a output must be connected to the corresponding M Bus meter All the M Bus outputs are connected in parallel Repeater Connect M Bus output of a further IZAR CENTER to the terminals 1 and 2 Connect terminal 5 or 6 with a protective ground potential Protective groun...

Page 16: ...g operational conditions M Bus Display Operational condition green 0 100 bus load yellow 100 130 bus load warning The maximum M Bus performance is achieved Do not connect further M Bus meters The IZAR CENTER is fully opera tional in this condition red Overload In this case too many M Bus meter are connected or the bus wires have a short circuit If there is a bus overload the M Bus volt age is swit...

Page 17: ... Green data are received Yellow data are sent 9 Maintenance The IZAR CENTER does not require any special mainte nance Do not use solvents or abrasive cleaning agents as these may damage the plastic housing If required use a cloth or moist sponge for cleaning 10 Storage The IZAR CENTER can be stored in a dry place at temper atures between 20 C and 70 C 11 Environmental note The device must not be d...

Page 18: ... is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is availa ble at the following internet address http www diehl com en diehl metering products solutions product download On this page please select Diehl Metering GmbH from the partner list and Metering Systems from the product list ...

Page 19: ...SB 3 Description IZAR CENTER envoie une requête aux compteurs connectés au M Bus Cette action peut être exécutée manuellement par l utilisateur ou automatiquement par l IZAR CENTER Pour un relevé du compteur automatique il faut disposer d un IZAR CENTER avec mémoire dans laquelle l inter valle de lecture générale ou spécifique est programmée Le compteur répond à cette requête en envoyant les valeu...

Page 20: ...automatique en plastique résistant à la chaleur ABS Classe de protection IP 20 Interfaces USB Ethernet LAN RS232 pour PC modem M Bus sortie et M Bus Répéteur entrée Taux de transmission M Bus 300 600 1200 2400 4800 9600 baud détection autobaud via RS232 Température de service 20 C 70 C L humidité de l air 10 90 l humi dité relative de l air sans condensation Poids env 472 g ...

Page 21: ...lité Elle incombe exclusivement à son auteur Seul un personnel qualifié est autorisé à installer ou à mettre en marche l IZAR CENTER 6 Montage Démontage Débrancher l alimentation prise 16 fig I avant le montage ou le démontage Montage de IZAR CENTER Clipser l IZAR CENTER sur le rail DIN Le crochet de fixation noir prise 65 fig I doit montrer vers le bas et l encliquetage doit être audible Démontag...

Page 22: ... est nécessaire Nous avons qualifié les prochains types M Bus connections Dehn BXT et Dehn Modul BXT ML2 BD S48 Diehl Metering Art No 3055664 LAN connections Dehn DPA M CAT6 RJ45 S48 Diehl Metering Art No 3055635 Il n est pas nécessaire de débrancher l alimenta tion pour connecter ou déconnecter un comp teur M Bus à l IZAR CENTER Borne prise Description 1 M Bus Répéteur entrée 2 M Bus Répéteur ent...

Page 23: ...AN Compteur M bus Connexion via la borne de sortie M Bus Le M Bus n est pas polarisé mais il faut utiliser une sortie et une sortie pour chaque compteur M Bus Toutes les sorties M Bus sont en parallèle Répéteur Connecter la sortie M Bus d un autre IZAR CENTER aux bornes 1 et 2 Connecter la Terre à la borne 5 ou 6 La Terre doit être connectée à IZAR CENTER Modem PC Connecter sur la prise 67 Utilise...

Page 24: ... fonctionnement vert 0 100 charge du bus jaune 100 130 charge du bus avertisse ment La performance maximale M Bus est atteinte Ne pas connecter plus de comp teurs M Bus Dans ce cas l IZAR CENTER est au maximum de sa capacité rouge Surcharge Dans ce cas trop de compteurs M Bus sont connectés ou la ligne M Bus est en court circuit S il y a une surcharge le courant M Bus est coupé pour env 2 secondes...

Page 25: ... Jaune données transmises 9 Entretien L IZAR CENTER n a besoin d aucun entretien particulier N utilisez pas des produits chimiques abrasifs et à base de solvant parce que le boîtier en plastique pourrait être endommagé Si nécessaire nettoyez avec un chiffon ou une éponge humide 10 Entreposage L IZAR CENTER peut être stocké à un lieu sec entre 20 C et 70 C 11 Faits concernant l environnement L appa...

Page 26: ...que du type IZAR CENTER est conforme à la directive 2014 53 UE Le texte complet de la déclaration UE de conformité est disponible à l adresse internet suivante http www diehl com fr diehl metering produits solutions documentation a telecharger Veuillez sélectionner le partenaire Diehl Metering GmbH et la rubrique Systèmes ...

Page 27: ......

Page 28: ...1583 1 6 2017 Technische Änderungen vorbehalten Technical changes reserved www diehl com metering Diehl Metering GmbH Industriestrasse 13 91522 Ansbach Phone 49 981 1806 0 Fax 49 981 1806 615 info dmde diehl com ...