Page 82
Updating Multiple Units Remotely
Use the following steps to update one or more iAM2-8 units remotely by
transferring the software from a previously updated iAM2-8:
1.
If any of the iAM2-8 units that you intend to update remotely may be in use,
contact the people using them and let them know what you will be doing.
The iAM2-8
units being updated will be temporarily out of service.
2.
Use the Wohler Web GUI to connect to an iAM2-8 already containing the
latest update. This will be referred to as the
Master Unit
. Navigate to the
System | System Update | Remote System Update
menu. The screen
shown in Figure A-12 will appear and the Web GUI will scan the network for
any active iAM2-8 units.
Figure A-12 – Scanning for iAM2-8 Units
Note:
The scanning process will take 2 minutes. Progress is shown on the
screen. If for some reason you would like to stop the scan prematurely, click the
Stop Scan
button.
Important:
Do not
run the scanning or updating process from
more than one
Master Unit
at a time, to avoid problems. Although you may be updating
multiple units at the same time, never attempt this process from more than one
Master Unit
.
3.
When the scanning is complete, a list of found iAM2-8 units will be shown as
in Figure A-13. Click either
Select All
or click only the
Target
units that you
want to update.