Page 23
Table 2–4: Meter Limits and References
2.
Ballistics
: The Bar and Float ballistics associated with the selected meter
scale are displayed. Refer to Table 2-5. Ballistic timings are valid only at 48
kHz.
Table 2–5: Meter Timings
Fall
Ballistics
Rise
Level
Change
Time
VU
Not Specified
IEC Type I
5 ms to reach -2 dB of
settled reading
-20 dB
1.7 sec.
IEC Type II
10 ms to reach -2 dB of
settled reading
-24 dB
2.8 sec.
None
Bar or Floating Segment Not Displayed
When you have made your choices, touch
Save
to retain them. Touch
Back
to exit
this screen.
Default Color
Bounds
Default Ballistics
Scale
Bottom Limit
Top Limit
Default
Reference
Lower
Upper
Float
Bar
AES
-72 dBFS
0.0 dBFS
0 dBFS = 0 dBFS
-30 dBFS -20 dBFS
IEC
Type I VU
DIN
-53 dBr
+5.5 dBr
-15 dBFS = 0 dBr
-5 dBr
0 dBr
—
IEC Type I
BBC
-13.25 dBr
+13.0 dBr
-18 dBFS = 0 dBr
0 dBr
8 dBr
—
IEC Type I
VU
-45 dBr
+3.5 dBr
-20 dBFS = 0 dBr
-3 dBr
0 dBr
—
VU
EXTVU
-56 dBr
+16.0 dBr
-20 dBFS = 0 dBr
-10 dBr
0 dBr
—
VU
NORDIC -44 dBr
+12.5 dBr
-18 dBFS = 0 dBr
-10 dBr
0 dBr
—
IEC Type I
EBU
-13.25 dBr
+13.0 dBr
-18 dBFS = 0 dBr
0 dBr
8 dBr
—
IEC Type I