Page 53
System Preferences
Click on
System Preferences
to find the Loudness and Phase Indicator
Configuration tabs. These are as shown in Figures 4-8 and 4-9.
Loudness Configuration Tab
The Loudness Configuration tab allows you to make settings which will determine
how Loudness is to be calculated on the Loudness Meter. This tab is shown in
Figure 4-8.
Figure 4–8: Loudness Configuration Tab
iAM-AUDIO2-8
The following settings can be made on this tab:
1.
Loudness Standard
: This is the loudness standard by which the loudness
calculation is made.
2.
Reference Level
: This is the set point in the loudness measurement about
which the determination is made as to whether an alarm should be displayed.
3.
LRA Window
: This is a moving window of time over which the loudness
measurement is made.
4.
Default Cluster
: When a Metering Screen is entered, this is the number of
the cluster that will initially be monitored for Loudness.
5.
Alarm
:
a.
Over
: The Alarm indication will only appear when Loudness has
exceeded the
Reference Level
by the
Tolerance
amount.
b.
Under
: The Alarm indication will only appear when Loudness is below
the
Reference Level
by the
Tolerance
amount.
c.
Both
: The Alarm indication will only appear when Loudness has
exceeded or is below the
Reference Level
by the
Tolerance
amount.
d.
Off
: The Alarm indication will not appear.
6.
Alarm Tolerance
: This is the range over which a normal loudness indication
is given. Above or below this range will result in color changes in the graph.