95
This is a security feature designed to let the monitoring station know that the device has
been reconfigured or attempted to be reconfigured.
The scan is active for both a configuration command sent over a local serial port, a TCP
connection, or an SMS message.
Successful config. CID code (fixed): 3222
Config failed. CID code (fixed): 3333
Partition: 99
Zone:
Interface
Interface
:
•
SMS
–
0x10
•
TCP
–
0x20
•
Serial
–
0x30
(6) Contact ID message sending in case of connecting trial with a bad
password
Description
The password required to connect and configure the device is monitored by the device
(this is also true for the local serial port (EasyTerm), TCP connection, and SMS for the
configuration command or message sent in the command).
If an incorrect password is entered, the device generates a special CID message and
transmits the corresponding fixed CID code.
This is a security feature designed to let the monitoring station know that an attempt has
been made to connect to the device with an incorrect password.
Enter wrong password CID code (fixed): 1461
Partition: 99
Zone:
Interface
Interface
:
•
SMS
–
0x10
•
TCP
–
0x20
•
Serial
–
0x30