48
Change the
GPRSEN
value to
Enable
, to operate the device as a cellular network transmitter.
At the
SFUNCT
parameter you can define that the primary or secondary server IP address will
be the first in the signaling sequence.
The
BACKUP
parameter allows a backup signaling to the centre through GSM voice - in case
of mobile network fall/outage.
The GSM-relevant parameters must be also configured
–
e.g.
SYS1
. (This should only be used
in mobile network relay mode!)
You can modify the
ACCOUNT
parameter value if you are attempted to signaling an own
customer ID for the identification. If it is not used, the BCDE code will be signaled.
The
LFFREQ
is the life signal sending frequency on GPRS channel, which is setup to 300
seconds by general. Check that it is fine or not. The
LFUNIT
value is the amount for the
LFFREQ
in seconds or minutes.
By
disabling
the
LFPRES
value you can send hidden life signals (P603) to the dispatcher
center/IP-receiver (if it is supported). By
enabling
it, the normal GPS value will be sended.
For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. The
program will indicates the configuration progress by the progress bar at the bottom of the
screen and at the
Terminal window
(3). At the end of the parameter sending, the device is
restarting by using the new settings.
Cellular network and APN settings
Then, let’s opent the
GPRS Service
parameter group for the
APN settings
. Then the program
will load the related parameters.
At the
APN
value, you have to define the APN name for the SIM-card related GPRS data
package service. When using a username or password are needed for the access
–
e.g. in case