84
Device restart, restrore of factory defaults, password
Command
Description
RESET
Restarts the device (manual restart which is needed to use
after every parametring SMS command)
ERASECONF
Deletion of every the stored parameters and settings from the
device memory (whole configuration delete)
Firmware refresh from the server
–
started by SMS command message
Command
Description
FWLOAD
Starting the Ftp firmware updates, with the already configured
ftp parameter settings
Important to define the necessary Ftp connection parameters to the succesful ftp firmware
update
–
as port, IP address, ftp username and password, etc.
Bypass
–
disabling a zone
–
specific commands
The
BYPASS
parameters can be only executed via SMS commands
–
and also possible to
control from the
EasyTerm
(
Bypass
tab).
Due to these, there is possible to disabling the alarm of the zones. By the
ARMBLOCK
parameter, when the
BYPASS
is
enabled
for the current zone, the device can be
armed
as
well (as an alarm system) - whether an opened zone.
In case of activated BYPASS for a zone, the events of the current zone will be not signaled as
alarms.
Command
Description
I
x
BYPASSON
Disabling the alarming for the nr.
x
input/zone
I
x
BYPASSOFF
Enabling the alarming for the nr.
x
input/zone
BYPASSON
Turning off the the alarming for all inputs/zones
BYPASSOFF
Turning on the the alarming for all inputs/zones