62
IVSMS
–
in case of unsuccessful calling/ringing the SMS notification sending can be enabled
When the call/ ring notification is not configured, it MUST BE enabled for the SMS notification!
The
IxON
parameter is used for SMS messaging for the changed input status (in case of level
change) It will be active, when the signal level is ascending (from low
→
high) or occuring (in
case of contact or wire cut). So define the status change / alarm event SMS text here.
While the
IxOFF
is active when the level is descending value from high
→
low (when the alarm
event will be ended (when the event will be recovered)). Define the status recovery / disarmed
state SMS text here.
SMSFWD
–
forwarding only messages in SMS text messages to the phone number #1 (the
mobile provider SMS notifications and SMS commands will be not forwarded).
For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At
the end of the parameter sending, the device is restarting by using the new settings.
Output / Siren operation settings:
For
configuring the siren/bark and output operation,
open
the
Output Settings
parameter
group and the program will load the related parameters.
The output control is deactivated in this mode by default, then setup the
OUTMODE
value to
Arm/Disarm
value.
If you are attempted to use and switch the siren then allow the input line alarm event to the
siren by the
SIRENOUT
parameter (in case of alerting, the siren will be turned on). The
SIRENDEL
defines the recovery time for the output (the siren will be turned off (muted) after
this defined interval).
For alarm system
arming or disarming
applying the „
bark”
sound can
enabled
by the
SIRENBARK
parameter.