52
In case of an occured input status change the detection of can be
enabled/disabled
by the
IxLHEN
(low-to-high signal, ascending level) and
IxHLEN
(high-to-low signal, descending
level) parameters for the input lines. Enable these for voltage and wire cut detection of wiring
type. (This is not relevant for the contact inputs.)
The signals are filtered through time frame (inputs must be sustained for a defined interval
with its current status and signal level to be detected).
The
IxARM
parameter is for granting that the current input line can transmit signal only in
Armed
status (value is
Armed
), or whether it is useful to transmit every status changes
–
even in
Disarmed
status (value is
24 hours
). The
armed
value is used for window & door
detectors/sensors by classic, the
24 hours
arming is capable of protecting the secured zones
–
as protecting the front door in
night mode.
The
end of line resistor
can be configured by the
IxEOL
parameter for the current input, to
detect cable wiring cut (sabotage detection feature). It generates alarm at every case.
If you’ve changed one of the listed
parameter values, then the program will highlight the