51
When it is necessary to define the current input line’s CID event code (
IxEVENT
), or the
partititon number (
IxPART
), zone (
IxZONE
) for monitoring sensors or a sabotage switch,
these parameters must be defined
(’
x
’
means the number of the input line in the name of the
parameter).
For sending the listed parameter values for the device (regarding the
Selected
coloumn)
–
check the proper selection
–
push the
Write config
button at the bottom of the screen. At
the end of the parameter sending, the device is restarting by using the new settings.
Input settings
For
configuring the
input lines operation
open the
Input Settings
parameter group and the
program will load the related parameters.
The device on its input lines it is capable of generating Contact ID codes and transmitting
them through wireless network/SMS notification in case of change (when ascending the
signal level (L→H)) or in case of recovery (descending (H→L)
level).
The length of this timeframe can be configured by
IDELAY
parameter, which can be
modded by 20msec steps. (By default it is
enabled
for inputs with 25msec value, which
means 500msec (half a second) delay.