55
WIKA operating instructions digital indicator, model DI35-D
EN
140553539.03 03/2020 EN/DE
PN Function
Parameter
Factory
setting
Authorisa-
tion level
Analogue output (option)
20
Full scale
-9999 ... 99999
10000
2
21
Start value
-9999 ... 99999
0
2
22
Reference value
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Arithmetic function
3
2
23
Output signal
0 = DC 0 ... 10 V
1 = 0 ... 20 mA
2 = 4 ... 20 mA
2
4
Interface
34
Interface properties
0 = Standard mode
1 = Transmission mode
0
4
User authorisation
50
Locking code
0000 ... 9999
0000
8
51
Release code
0000 ... 9999
0000
0
52
Authorisation level
0 ... 8
8
0
Special functions
53
Function of the digital
input
0 = Deactivated
1 = Switching the measur-
ing input
2 = HOLD
3 = TARE
0
2
54
Function of the multi-
function key
0 = Deactivated
1 = Switching the measur-
ing input
2 = HOLD
3 = TARE
0
2
55
TARE function
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Measuring input 1 + 2
0
2
56
HOLD function
0 = Deactivated
1 = Triggered
2 = Static
0
2
Appendix 1: Overview of program numbers