24
WIKA operating instructions digital indicator, model DI35-D
EN
7.1.2 Start and end value
With this value pair, the measuring signal is assigned the desired indication value.
PN Function
Parameter
1
End value (end of measuring range)
Measuring input 1
-9999 ... 99999
2
Start value (start of measuring range)
Measuring input 1
-9999 ... 99999
6
End value (end of measuring range)
Measuring input 2
-9999 ... 99999
7
Start value (start of measuring range)
Measuring input 2
-9999 ... 99999
Procedure for standard signals
▶
Set the corresponding display values.
Procedure for non-standard input signals
1. Apply the end value of the input signal to the measuring input.
2. Select PN 1/PN 6.
3. Set the display value.
4.
Press [☼].
⇒
Input signal is associated with display value.
5. Apply the start value of the input signal to the measuring input.
6. Select PN 2/PN 7.
7. Set the display value.
8.
Press [☼].
⇒
Input signal is associated with display value.
⇒
Display values are assigned.
7. Description of program numbers
140553539.03 03/2020 EN/DE