33
WIKA operating instructions digital indicator, model DI35-D
EN
PN
Function
Parameter
55
TARE function
0 = Deactivated
1 = Measuring input 1
2 = Measuring input 2
3 = Measuring input 1 + 2
7.7.4 HOLD function
The HOLD function freezes the current display value. This is signalled via a flashing
display.
The HOLD function can be activated through the multi-function key or the digital input (→
see chapter 7.7 “Setting special functions”).
The HOLD function can be switched statically or triggered.
Method
Description
Static
A display value is frozen for the duration of the trigger signal.
Triggered
The display value is frozen as soon the trigger is activated for
a short time. The function is reset when the trigger is activated
again.
PN
Function
Parameter
56
HOLD function
0 = Deactivated
1 = Triggered
2 = Static
7. Description of program numbers