53
WIKA operating instructions digital indicator, model DI35-D
EN
140553539.03 03/2020 EN/DE
Appendix 1: Overview of program numbers
PN Function
Parameter
Factory
setting
Authorisa-
tion level
Measuring input 1
0
Measuring input
0 = N/A
Factory calibration
1 = DC 0 ... 10 V
2 = 0 ... 20 mA
3 = 4 ... 20 mA
Sensor calibration
4 = DC 0 ... 10 V
5 = 0 ... 20 mA
6 = 4 ... 20 mA
0
2
1
Full scale
-9999 ... 99999
10000
2
2
Start value
-9999 ... 99999
0
2
3
Decimal places
00000 ... 0.0000
00000
2
4
Offset adjustment
-9999 ... 99999
0
2
Measuring input 2
5
Measuring input
0 = N/A
Factory calibration
1 = DC 0 ... 10 V
2 = 0 ... 20 mA
3 = 4 ... 20 mA
Sensor calibration
4 = DC 0 ... 10 V
5 = 0 ... 20 mA
6 = 4 ... 20 mA
0
2
6
Full scale
-9999 ... 99999
10000
2
7
Start value
-9999 ... 99999
0
2
8
Decimal places
00000 ... 0.0000
00000
2
9
Offset adjustment
-9999 ... 99999
0
2
Appendix 1: Overview of program numbers