28
WIKA operating instructions digital indicator, model DI35-D
EN
PN
Function
Parameter
15
Calculation type
1 = Measuring input 1 ∙ constant
2 = Measuring input 2 ∙ constant
3 = Addition
4 = Subtraction
5 = Multiplication
6 = Ratio
7 = Percent
16
Constant
-9999 ... 99999
17
Number of decimal places of constants
00000 ... 0.0000
18
Number of decimal places of calculation
00000 ... 0.0000
With the calculation of the arithmetic function, all set decimal points are
included (PN 3, PN 8, PN 17, PN 18)
7.4 Setting the analogue output (option)
The analogue output gives the measured values of the digital indicator as a standard
signal (DC 0 ... 10 V, 0 ... 20 mA, 4 ... 20 mA).
7.4.1 Start and end value
The analogue output can be assigned any measuring input. The output signal is
updated simultaneously with the measuring input. The refresh rate is determined by
the configured measuring time. The start and end value for the analogue signal can be
assigned user-defined measured values.
The start and end value defines at which display value the minimum and maximum
output signal will be given. The display value is dependent upon the setting of the input
signal ( see chapter 7.1.1 “Input signal”)
PN
Function
Parameter
20
Full scale
-9999 ... 99999
21
Start value
-9999 ... 99999
7. Description of program numbers