Glass and Material Lift
GML 800+
15
Operating Manual
GML 800+
Safety Instructions
Electrocution Hazards - Danger to Life
This lift is not electrically insulated and will not provide
protection from contact with or proximity to electrical current.
Keep away from the lift if it comes into contact with
electrical power cables. Personnel must not touch or
operate the lift until the power conductors have been
switched off.
Maintain safe distances away from electrical power conductors
and appliances.
Please take into account the relevant current legal regulations
and the following chart:
Allow for mast movement and possible swaying and sagging
of electrical cables. Be especially careful in strong or gusty
wind conditions!
The unit is not to be used in conjunction with welding units
fitted to the forks under any circumstances...
Injury Hazard
Do not hold on the winch cable and do not reach into the winch
itself.
Do not rest ladders or scaffolding against the lift or the
load.
Do not operate the lift on a movable/mobile surface or
on a motor vehicle.
The Safe Working Load (SWL) must not be exceeded
under any circumstances. Always refer to the load
charts on the unit.
Avoid moving the lift with closed outriggers over debris or
uneven ground.
Never replace lift parts that are important for stability
or construction with parts with different weights and
specifications. Only use original replacement parts.
If the equipment is damaged or operating incorrectly
you must contact the hirer immediately.
Only use the approved loading accessories with this lift.
Lifting Hazards
Always use the correct lifting techniques when loading or
tilting the lift. Personnel should be trained and competent
to use the unit correctly.
Always ensure that the correct lifting techniques is used
when installing and disassembling the loading
accessories.
Operating the Lift
Ensure that the safety brakes are engaged prior to operating
the lift in order to avoid rolling.
Do not ever stand or allow others to stand under the loading
accessories.
Always remain behind the winch when raising or lowering.
Do not stand on the chassis, the outriggers or any other
components.
Meters
Avoid Contact
3,1 m
4,6 m
6,1 m
7,6 m
10,7 m
13,7 m
Phase-to-Phase
0 - 300 V
300 V - 50 kV
50 kV - 200 kV
200 kV - 350 kV
350 kV - 500 kV
500 kV - 7550 kV
750 kV - 1000 kV
MINIMUM SAFETY DISTANCE
VOLTAGE