R7F4HEIP-DAC16B

BEFORE USE ....

Thank you for choosing M-System.  Before use, please check 
contents of the package you received as outlined below.
If you have any problems or questions with the product, 
please contact M-System’s Sales Office or representatives.

 

PACKAGE INCLUDES:

Discrete I/O module ............................................................(1)
DIN rail mounter slider ......................................................(2)

 

MODEL NO.

Confirm Model No. marking on the product to be exactly 
what you ordered.

 

INSTRUCTION MANUAL

This manual describes necessary points of caution when 
you use this product, including installation, connection and 
basic maintenance procedures.

 

EDS FILE

EDS files are downloadable at M-System’s web site: https://
www.m-system.co.jp

POINTS OF CAUTION

 

CONFORMITY WITH EU DIRECTIVES

• The equipment must be mounted inside the instrument 

panel of a metal enclosure.

• The actual installation environments such as panel con-

figurations, connected devices, connected wires, may af-
fect the protection level of this unit when it is integrated 
in a panel system.  The user may have to review the CE 
requirements in regard to the whole system and employ 
additional protective measures to ensure the CE conform-
ity.

 

POWER INPUT RATING & OPERATIONAL RANGE

• Locate the power input rating marked on the product and 

confirm its operational range as indicated below:

    24V DC rating: 24V ±10%, approx. 70mA

 

GENERAL PRECAUTIONS

• Before you remove the unit or mount it, turn off the power 

supply and input signal for safety.

• Before you remove the terminal block or mount it, make 

sure to turn off the power supply and input signal for 
safety.

• DO NOT set the switches on the module while the power 

is supplied. The switches are used only for maintenance 
without the power.

 

ENVIRONMENT

• Indoor use.
• When heavy dust or metal particles are present in the 

air, install the unit inside proper housing with sufficient 
ventilation.

• Do not install the unit where it is subjected to continuous 

vibration.  Do not subject the unit to physical impact.

• Environmental temperature must be within -10 to +55°C 

(14 to 131°F) with relative humidity within 30 to 90% RH 
in order to ensure adequate life span and operation.

• Observe at the minimum of 10 mm left and right the 

units for heat dissipation when mounting vertically.

 

WIRING

• Do not install cables close to noise sources (relay drive 

cable, high frequency line, etc.).

• Do not bind these cables together with those in which 

noises are present.  Do not install them in the same duct.

• Be sure to close the terminal cover for safety.

 

AND ....

• The unit is designed to function as soon as power is sup-

plied, however, a warm up for 10 minutes is required for 
satisfying complete performance described in the data 
sheet.

Содержание R7F4HEIP-DAC16B

Страница 1: ...protective measures to ensure the CE conform ity POWER INPUT RATING OPERATIONAL RANGE Locate the power input rating marked on the product and confirm its operational range as indicated below 24V DC rating 24V 10 approx 70mA GENERAL PRECAUTIONS Before you remove the unit or mount it turn off the power supply and input signal for safety Before you remove the terminal block or mount it make sure to t...

Страница 2: ... the signal status ON LED ON OFF LED OFF IP ADDRESS Set the host address 2 digit hexadecimal number in the IP address using rotary switches SA1 and SA2 for the first digit and the second digit respectively When using the host address in the IP address set on the PC configurator software model R7CFG set the switches to 00H When the network address Subnet Mask and Default Gateway need to be changed ...

Страница 3: ... 46 47 48 49 50 51 52 PIN No ID FUNCTION PIN No ID FUNCTION 1 24V1 24V DC 27 24V2 24V DC 2 X0 Input 0 28 Y0 Output 0 3 24V1 24V DC 29 24V2 24V DC 4 GND1 0V 30 GND2 0V 5 X2 Input 2 31 Y2 Output 2 6 24V1 24V DC 32 24V2 24V DC 7 GND1 0V 33 GND2 0V 8 X4 Input 4 34 Y4 Output 4 9 24V1 24V DC 35 24V2 24V DC 10 GND1 0V 36 GND2 0V 11 X6 Input 6 37 Y6 Output 6 12 24V1 24V DC 38 24V2 24V DC 13 GND1 0V 39 GND...

Страница 4: ...move the upper hook of the unit from the DIN rail 1 2 3 SURFACE MOUNTING 1 Insert the two DIN rail mounter sliders until it clicks once as shown below 1 1 2 Mount the unit with M4 screws referring to the External Dimensions Torque 1 4 N m DIN RAIL MOUNTING RIGHT ANGLE Mounting 1 Insert the longer DIN rail mounter slider until it clicks twice as shown below 2 Set the upper hook at the rear side of ...

Страница 5: ...mm wide 2 4 3 dia 4 deep CONNECTION DIAGRAM Note In order to improve EMC performance bond the FE terminal to ground Caution FE terminal is NOT a protective conductor terminal 1 The network cable can be connected to either one 1 EtherNet IP RJ 45 MODULAR JACK 1 EtherNet IP RJ 45 MODULAR JACK 3 4 2 25 26 24 1 14 29 30 28 51 52 50 27 40 4 5 1 24V DC FE 0V 24V1 X7 GND1 24V2 Y0 GND2 24V2 Y7 GND2 24V1 G...

Страница 6: ... software model R7CFG Refer to the users manual of the software for detailed operations CHANNEL BATCH SETTING PARAMETER SETTING RANGE DEFAULT SETTING Conversion rate 1 ms 5 ms 10 ms 20 ms 50 ms 70 ms 100 ms 200 ms 10 ms Output Hold Clear Hold Clear Hold ETHERNET SETTING PARAMETER SETTING RANGE DEFAULT SETTING IP Address 0 0 0 0 255 255 255 255 192 168 0 250 Subnet Mask 0 0 0 0 255 255 255 255 255 ...

Страница 7: ...ing command on the Windows MS DOS as follows C WINDOWS ping Enter IP address in decimal ping with 32 bytes of data Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Reply from bytes 32 time 10ms TTL 64 Ping statistics for Packets Sent 4 Received 4 Lost 0 0 loss Replies in case of normal connection are as shown above If the connection can...

Отзывы: