5-2
Refer to page 4-2 for the procedure for servic-
ing the water inlet valves.
1.
Unplug washer or disconnect power.
2.
Disconnect the wires from the water inlet
valve solenoid terminals.
3.
Set the ohmmeter to the R x 100 scale.
4.
Touch the ohmmeter test leads to the hot
and cold water inlet valve solenoid termi-
nals. The meter should indicate between
890 and 1090
Ω
for both solenoids.
DRIVE MOTOR CAPACITOR
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
COLD (BLUE) HOT (RED)
Terminals
WATER INLET VALVE SOLENOIDS
Capacitor Connectors
Refer to page 4-14 for the procedure for servic-
ing the drive motor capacitor.
1.
Unplug washer or disconnect power.
2.
Disconnect the wires from the capacitor
terminals.
3.
Set the ohmmeter to the R x 1K scale.
4.
Touch the ohmmeter test leads to the
capacitor terminals. The meter should
momentarily deflect toward 0
Ω
and then
reverse direction toward infinity.