page A – 6
AM-55 / Sep 2015
A P P E N D I C E S
Power Requirements:
100‑250 VAC (auto sensing)
50/60Hz,
100
VA
Max.
Power Connector:
EMI suppressed IEC male
Shipping
Weight: 15
pounds
Operating Temperature:
0 to 50 degrees C (32 to 122 degrees F)
Overtemp
alarm
reporting
via
GUI
* Bypass Preset, unity gains, and no pre‑emphasis.
All specifications subject to improvement or change without notice.
Preset Management
The AM‑55’s advanced preset management system allows the creation, storing, and
recall of 80 presets within the AM‑55 itself and an unlimited number may be stored on the
Windows PC hosting the GUI. In addition to processing parameters, all System parameters
are stored within presets allowing the preservation of the complete processing “environment.”
Optionally, Input and Output settings may be stored and recalled with presets.
Preset Encryption
Presets are encrypted using the AM‑55 internal 32 bit serial number as the encryption
key.
General Purpose Interface (GPI)
The AM‑55 is equipped with the ability to have General Purpose Input/Output closure
via RJ‑45 supplied on the rear of the unit. Refer to Chapter 1 page 1‑10 for details.
Ethernet Interface
The AM‑55 contains an auto‑sensing 100BaseT Ethernet switch with one port available
on the outside of the unit for field use. Because the switch is auto-sensing it is not necessary
to utilize a crossover cable when connecting a PC directly to the AM‑55.
Software Remote Control
Supplied Windows® AM‑55 GUI software affords control of all system and processing
parameters via a 100BaseT Ethernet interface.