49
JUG DISCOUNT – Address 260
Range of discount available = 1 to 9.99. The value set within this address will
determine the discount per cup, i.e. if address 260 = 2 and it takes 5 cups to fill
a jug; the total discount will equal 10. This facility is not applicable during a
timed supplementary period.
0 = No discount for jug-fill vends.
PRICE INCREASE FOR STRONG DRINKS - Address 262
The content of this Address enables a price increase on selecting a Strong
drink. The default setting of 0 disables the feature. Any other parameter will set
the price increment, that is the value to be added to the selling price of the
regular selection, e.g. a value of 2 will increase the selling price by 2, when a
strong drink is selected. The pricing for a strong drink shall be initiated by
pressing the ‘Strong’ key on the keypad, up to a maximum of three times.
PRICE INCREASE FOR EXTRA WHITE SELECTIONS - Address 263
The content of this Address enables a price increase on selecting the Extra
White option. The default setting of 0 disables the feature. Any other
parameter will set the price increment, that is the value to be added to the
selling price of the regular selection. The pricing for extra milk shall be initiated
by pressing the ‘Extra White’ key on the keypad, up to a maximum of three
times.
PRICE INCREASE FOR EXTRA SUGAR SELECTIONS - Address 264
The content of this Address enables a price increase on selecting the Extra
Sugar option. The feature is disabled (by default) when set to 0. Any other
parameter will set the price increment, that is the value to be added to the
selling price of the regular selection. The pricing for extra sugar shall be
initiated by pressing the ‘Extra Sugar’ key on the keypad, up to a maximum of
three times.
CUP & VEND AUDIT MODE - Address 265
The content of this address enables the method to ‘charge for a cup’ or
‘discount for cup’ to be audited and price controlled accordingly.
0 =
Discount for No-cup in audit & pricing (default)
1 = Charge for cup in audit & pricing.
Note: An audit reset will need to be preformed if a change is made to this
address.
INSTANT WATER FLUSH LEVEL – Address 340
The value entered within this address, in seconds, will determine the amount of
time the water valve will be initiated for on all instant selections during a flush
cycle.