UV FILTER SETUP – Address 66
To enable or disable UV filter inhibit, Address 67
0 = Disabled
1 = Enabled
UV FILTER INHIBIT – Address 67
Sets the value for the number of vends allowed before the ‘Change UV Lamp‘
is displayed, i.e. 20000 = 20,000 vends.
0 = Disabled
CUP SETUP – Address 90
0 = Permanent No Cup
1 = Cup Drop Active
2 = Hot Cups Only, No Cup for Cold Drinks
SETUP CUP SENSOR – Address 91
0 = Disabled
1 = Enabled & Will warn of no cup detection & will not vend a drink
2 = Enabled & will warn of no cup detection, will vend a drink on the second
press of the ‘Vend’ key within 10 seconds
MOVING DISPENSE HEAD, ARM MOVMENT STALL TIMEOUT – Address 75
The time set within this address determines the delay period from the start of
the vend before activating an alarm, error code 30, indicating the arm has
stalled, jammed or failed to be detected by either switch.
5 = 5 Seconds (Default)
MOVING DISPENSE HEAD,
DELAY TIME AFTER VEND
– Address 76
This address sets a time delay after the vend has completed before allowing
the arm to be returned to the ‘home ‘ position.
1 = 1 Seconds (Default)
MOVING DISPENSE HEAD,
NOMINATED CONTROL TRIAC
– Address 77
0 = Off
1 = 22 (SKT 11-12 Output, reserved for Hot Water)
2 = 28 (SKT 12-6 Output, reserved for Syrup 2)
3 = 30 (SKT 12-8 Output, reserved for Grinder Pump)
(See connector outputs – Chapter 23)
MOVING DISPENSE HEAD, SENSOR SWITCH INVERT – Address 78
0 = NC - Normally Closed
1 = NO - Normally Open (Default)