COIN A TO C ASSIGNMENTS - MDB Addresses 218 – 223 (Cont.)
Example: An MDB coin mechanism is fitted with a 5, 10, 20, 50p validator.
To set a low change condition when the 5p tube drops below 10 coins or the
10p tube drops below 8 coins, the following needs to be set.
Address 218 to
5 (Coins A and B, Default setting)
Address 219 to
10 (Low level for coin A)
Address 220 to
8 (Low level for coin B)
Address 221 to
0 (Identifies coin A as the lowest coin denomination,
default setting 5p)
Address 223 to
1 (Identifies coin B as the second lowest coin
denomination, default 10p)
NOTE:
Some MDB coin mechanisms do not have the facility to count the number of
coins allocated to the tubes. These mechanisms rely upon high and low level
sensors within each tube.
In order for the exact change equation to function correctly the tube low levels,
in Addresses 351 to 353, will need to be set below the number of coins at
which the low level sensor operates.
EXACT CHANGE EQUATION – Address 224
Specifies when "use exact change only" is displayed i.e., when certain coin
tubes reach the low settings.
0 = A or (B and C)
1 = A and B and C
2 = A and B
3 = A and (B or C)
4 = A
5 = A or B
6 = A or B or C
7 = A and C
8 = A or C
9 = B and C
10 = B
11 = B or C
12 = C
EXACT CHANGE MESSAGE DISPLAY – Address 225
0 = Alternate
1 = Permanent when applicable
MAXIMUM CREDIT - MDB Address 226 (Default setting = 0200)
The maximum value of credit accepted as a multiple of the lowest value coin
accepted.