29
ADD
FUNCTION
DEFAULT COMMENT
48
VEND DELAY
5
TIME IN SECONDS, 0 = AUTO VEND FEATURE DISABLED.
51
JUG AVAILABLE
0
0 = DISABLED 1 = ENABLED
52
MAX NUMBER CUPS PER JUG
7
53
CHANGE WATER FILTER WARNING
20000 0 - DISABLED
66
UV FILTER SETUP
0
0 = DISABLED, 1 = ENABLED
67
UV FILTER INHIBIT
20000 0 - DISABLED
75
M.D.H. ARM MOVMENT STALL TIMEOUT
5
MOVING DISPENSE HEAD, ARM MOVMENT STALL TIMEOUT
76
M.D.H.
ARM HOME START DELAY
1
MOVING DISPENSE HEAD,
DELAY TIME AFTER VEND
77
M.D.H.
NOMINATED CONTROL TRIAC
0
MOVING DISPENSE HEAD,
OUTPUT:
0 = OFF
1 = 22 - HOT WATER OR MDH
(OUTPUT SKT 11, PIN 12)
2 = 28 - SYRUP 2 OR MDH
(OUTPUT SKT 12, PIN 6)
3 = 30 - GRINDER PUMP OR MDH
(OUTPUT SKT 12, PIN 8)
78
M.D.H. SENSOR SWITCH INVERT
1
MOVING DISPENSE HEAD, 0= NC, 1 = NO
CUP SETTINGS
90
CUP SETUP
1
0 = PERMANENT NO CUP
1 = CUP DROP ACTIVE
91
SET UP CUP SENSOR
0
0 = DISABLED
1 = ENABLED & WILL WARN OF NO CUP DETECTION & WILL
NOT VEND A DRINK
2 = ENABLED & WILL WARN OF NO CUP DETECTION, WILL
VEND A DINK ON THE SECOND VEND PRESS WITHIN 10
SECONDS
92
CUP SENSOR OPERATION
0
0 = DISABLED, VEND WILL NOT ABORT
1 = ENABLED WILL ABORT VEND IMMEDIATELY. WILL EMPTY
BREWER IF FRESHBREW DRINK
2 = ENABLED, WILL ABORT IMMEDIATELY, THEN RINSE THE
BOWLS FOR 2 SECONDS, ALSO EMPTY THE BREWER IF
A FRESHBREW DRINK
93
NO CUP KEY DISABLE
1
0 = CUP DISABLED
1 = CUP ENABLED
2 = AUTO NO CUP DETECTION
94
DEFAULT CUP SIZE
0
0 = REGULAR, 1 = LARGE
95
FB DRINK QUICK VEND ENABLE
0
0 = DISABLED, 1 = ENABLED
96
BTC DRINK QUICK VEND ENABLE
0
0 = DISABLED, 1 = ENABLED
98
MAX BOWL RINSE TIME
2.0
100
CAROUSEL TIMEOUT
120
101
PEELER MOTOR - TIMEOUT
9.0
102
PEELER CUP EMPTY LEVEL
3
SETS THE LEVEL OF CUPS REMAINING IN THE PEELER
AFTER THE CAROUSEL START TO LOAD, BEFORE VENDS
ARE INHIBITED
BOILER SETTINGS
115 BOILER
OPERATING
TEMPERATURE
80 BOILER NORMAL TEMPERATURE SETTING
116 BOILER
SLEEP
TEMPERATURE
60 BOILER SLEEP TEMPERATURE SETTING
117 AUTO
SLEEP
DELAY
0
INACTIVITY TIME AFTER WHICH THE BOILER GOES TO
SLEEP.
118
BOILER TEMPERATURE CURRENT
READING
N/A
READ ONLY
119
BOILER TEMPERATURE OVERFLOW
READING
N/A
READ ONLY
120
BOILER TEMPERATURE MAXIMUM
READING
N/A
READ ONLY
121
BOILER FILL TIMEOUT
180
122
BOILER TEMP EXCEED TIMEOUT
120
123
BOILER HEAT ON TIMEOUT
900
124
BOILER CALIBRATION
N/A