109
Error code 59 - Thermistor Probe Fault.
With the machine switched off remove SKT 7 from the processor board, using
the ‘graph of resistance versus temperature’ chart measure the resistance
across pins 1 and 2 (over temperature probe) and across pins 3 and 4
(operating temperature probe). If the resistance falls out side 900 ohms to 1K6
ohms replace the relevant probe (P/N 100021040), if the resistances are within
the parameters replace the processor board (P/N 190010).
Error code 60 – Grinder Timeout
For additional information, see section 13. BREWER, GRINDER AND DOSING
SWITCH
SWITCH MACHINE OFF
Set your voltmeter to measure
continuity
Manually operate the dosing
switch on the top of the dosing
motor; is continuity measured
across the legs?
Replace switch
(P/N FAS 240-
00115B)
N
Remove Bean canister and clear
any blockages to the dosing
switch.
Retest machine, if fault persists
SWITCH MACHINE OFF
Remove SKT 4
and operate
dosing switch is
continuity
measured
across pin 1
(White/Red) and
pin 13
(Red/White)?
Y
Locate break
in loom
N
Check to ensure the dosing
switch is turned on within the
programming of the machine.
Y
Replace processor
board (P/N
190010)
Y