Westell AISG-RM3 Скачать руководство пользователя страница 20

Section AIS‐RM3‐20B

030‐101806 Rev. A

R

1310IBRA

20

Code

Message

Alarm

Description

0x00

OK

0x01

Actuator Detection Fail

X

0x02

Actuator Jam Permanent

X

0x03

Actuator Jam Temporary

X

0x04

Block Number Sequence Error

0x05

Busy

0x06

Checksum Error

0x07

Command Sequence Error

0x08

Data Error

0x09

Device Disabled

0x0A

EEPROM Error

X

0x0B

Fail

0x0C

Flash Erase Error

X

0x0D

Flash Error

X

0x0E

Not Calibrated

X

0x0F

Not Scaled

X

0x11

Other Hardware Error

X

0x12

Other Software Error

X

0x13

Tilt out of Range

X

0x14

Position Lost

X

0x15

RAM Error

X

0x16

Segment Number Sequence Error

0x17

UART Error

X

0x19

Unknown Command

0x1A

TMA Alarm Minor

X

0x1B

TMA Alarm Major

0x1C

Gain out of Range

0x1D

Read Only

0x1E

Unknown Parameter

0x1F

Bypass Mode

0x21

Software Missing

0x22

Invalid File Content

0x24

Format Error

0x25

Unsupported Proc

0x26

Invalid Proc Sequence

0x27

Actuator Interference

X

0x51

Uninitialized

X

Cannot get device information after a scan process.

0x52

Bad Responding

X

Bad communication between the AISG‐RM3 system and the device.

0x53

No Responding

X

Lost connection between the AISG‐RM3 system and the device.

0x54

Function Fail

Unexpected result from the AISG‐RM3 system.

0x59

Timeout

The response time from the device to the AISG‐RM3 has timed out.

0x70

Default Result

Unexpected or unknown result.

0x71

Error

General error.

0x72

File I/O fail

File access fails.

0x73

System Timeout

Waiting for response from the AISG‐RM3 has timed out.

0x77

Add device fail

Failed to add a device.

0x78

Value is empty

Input field does not allow empty value.

0x79

Field name is null!

Invalid field name is used on the web interface.

0x7A

Antenna model config file does not exist!

The antenna configuration data file doesn't exist.

0x7B

Device exists!

The device already exists in the AISG‐RM3 system.

0x7C

Size is too large!

The file size of antenna configuration data is too large.

0x7D

The max. number of files reached!

The number of antenna configuration data files has reached the limits defined in the
controller system.

0x7E

Total file size exceeds

The total file size of antenna configuration data files in the controller system has
reached the limits defined in the system.

Table 17.    Error and Alarm Codes

Содержание AISG-RM3

Страница 1: ...son will be stated here This document reflects the Issue B equipment which accepts an input power supply range of 48VDC to 24VDC and uses con tact relays as alarm outputs Figure 1 AISG RM3 AISG Contro...

Страница 2: ...a reset button and three LEDs as shown in Table 1 and Table 4 below and ex plained in the paragraphs that follow LED Color State Status Description ALM alarm Red Steady AISG RM3 cannot ping default g...

Страница 3: ...C Normally Closed relay output Contact Capacity AC 125V 0 5A DC 24V 1A N O Normally Open relay output COMM Common N A GND Ground of I O channels Ground Table 3 Alarm Connector Pin outs 2 2 5 Ethernet...

Страница 4: ...ent Any in structions or information contained herein is subordinate to local codes operating procedures or practices CAUTION Improper grounding could be service affecting and cause service interrupti...

Страница 5: ...f the controller has been preset to 192 168 0 30 Enter this IP address for first time access It can be changed later The browser should display the Login page as shown in Figure 7 Figure 7 Login Scree...

Страница 6: ...enna Config File _ Summary Report _ Site Information _ Logout _ System Setting 4 1 Configure the System Settings Click on the System Setting tab as shown in Figure 11 to open the System Setting menu T...

Страница 7: ...age and power supply mode provided to the connected AISG devices can be changed Change the settings per company practice refer ring to Table 6 as needed then click on the Set button to apply the chang...

Страница 8: ...before triggering the alarm output This helps to remove any spurious non real alarm conditions 4 2 Manage User Accounts Click on the System Account tab on the main menu to open the user list accounts...

Страница 9: ...ized device is listed in the RET or TMA device list section panel according to its device type Devices are sorted by Sector ID in ascending order Scanning retrieves information previously stored in ea...

Страница 10: ...you are adding The Vendor Code is optional Click on the Add button to initiate the process If the process is successful the Device List will be updated Save the device information before moving on 5...

Страница 11: ...lf of a selected device screen Figure 31 shows detailed information about the an tenna connected to the selected AISG device Table 10 explains the fields and options in the Antenna Data section or pan...

Страница 12: ...lowed electrical down tilt range of the selected an tenna model Current Tilt Current electrical tilt Tilt value must be in the Min Tilt Max Tilt range If the tilt value cannot be retrieved the data va...

Страница 13: ...ISG version supported by the TMA device Figure 38 Viewing a Specific TMA Shown in Device List The fields in the selected TMA Device panel are listed in Table 12 Field Name Description Constraint Optio...

Страница 14: ...ation window below is displayed Click on the OK button to initiate the process of chan ging the TMA gain After the process is done close the message window 5 2 3 4 Get Gain Click on the Get Gain butto...

Страница 15: ...TMA Gain SET_MODE Sector ID mode Set TMA Mode Note The key word in the Action column is used in the log to represent the recorded action Information re lated to an action in the Information Recorded c...

Страница 16: ...n one vendor code the vendor code is also shown after the vendor name Select the vendor name with the right vendor code to upload the configuration file The vendor code must match the vendor code on t...

Страница 17: ...the AISG RM3 controller Set the terminal connection settings to Baud Rate 9600 Stop bits 1 Data bits 8 No Parity 7 2 Using Console Commands Once connection with the AISG RM3 controller is established...

Страница 18: ...ke effect 15 Set System Date Time Changes the system UTC date and time 16 Set 12v 24v Power Setting Switches 12V 24V DC on or off The default is N which represents off Table 16 Command Display Numbers...

Страница 19: ...rmware Once finished perform a manual reboot of the controller 3 Refresh the browser to reload the user interface you will find the changed upgraded firmware 9 ERROR ALARM CODES MESSAGES The following...

Страница 20: ...n between the AISG RM3 system and the device 0x53 No Responding X Lost connection between the AISG RM3 system and the device 0x54 Function Fail Unexpected result from the AISG RM3 system 0x59 Timeout...

Страница 21: ...ling programs and local codes and per state statutes 12 SPECIFICATIONS 12 1 Electrical Specifications A Power supply input DC 24V max 3 2A or 48V max 1 6A B Power supply to AISG devices 24V max 2 0 A...

Страница 22: ...Amplifier LTE Long Term Evolution mA milliAmps MHz Megahertz PDU Power Distribution Unit RES Receiver Enhancement System RF Radio Frequency Rx Receive TMA Tower Mounted Amplifier Tx Transmit V Volts...

Отзывы: