Pro-EC44 2-Loop Graphical Profile Controller & Recorder
Pro-EC44 Product Manual - 59540-2 September 2014
Page 177
LED 1 Usage
Value
LED 1 Usage.
For 8 & 9 see also LED 1 Selections.
Dec
7664
24048
48096
RW
0
Loop 1 Primary Control ON = LED 1 ON
Hex
1DF0
5DF0
BBE0
1
Loop 1 Secondary Control ON = LED 1 ON
2
Loop 2 Primary Control ON = LED 1 ON
3
Loop 2 Secondary Control ON = LED 1 ON
4
Loop 1 VMD Open ON = LED 1 ON
5
Loop 1 VMD Close ON = LED 1 ON
6
Loop 2 VMD Open ON = LED 1 ON
7
Loop 2 VMD Close ON = LED 1 ON
8
Alarm/Event/Digital/Control (Logical
OR
)
9
Alarm/Event/Digital/Control inverted (Logical
NOR
)
Value 8 (Logical
OR
selection of Alarm/Events/Digital/Control) turns
ON
the LED if any of the selected
alarms, events, inputs or functions are active.
Value 9 (Logical
NOR
selection of Alarm/Events/Digital/Control) turns
OFF
the LED if any of the selected
alarms, events, inputs or functions are active.
Note:
Pre-tune will flash the LED instead of turning it on, but flashing will be obscured if used in
conjunction with other functions when they are on.
LED 1 Alarm Indication
Bit
If bit =1, Alarm
n
status is selected
Dec
7690
24074
48148
RW
0
Alarm 1
Hex
1E0A
5E0A
BC14
1
Alarm 2
2
Alarm 3
3
Alarm 4
4
Alarm 5
5
Alarm 6
6
Alarm 7
LED 1 Profiler Event Indication
Bit
If bit =1, Event
n
status is selected
Dec
7692
24076
48152
RW
0
Event 1
Hex
1E0C
5E0C
BC18
1
Event 2
2
Event 3
3
Event 4
4
Event 5
5
Profile Running
6
Profile End
LED 1 Slot A & Soft Input Indication
Bit
If bit =1, Digital A / Soft Input
n
status is selected
Dec
7694
24078
48156
RW
0
Digital Input A
Hex
1E0E
5E0E
BC1C
1
Soft Digital 1
2
Soft Digital 2
3
Soft Digital 3
4
Soft Digital 4
Содержание Pro-EC44
Страница 1: ...Pro EC44 2 Loop Graphical Profile Controller Recorder Pro EC44 User Guide 59540 2 ...
Страница 2: ......
Страница 6: ......