31
CapaCiTiES
aNd
raTiNgS
A. Ceiling Capacity ............................................................100 lb./sq.ft.
B. Power Requirements
The recommendation for power connections to V-Room Practice is that each room
must have one dedicated 20A circuit.
Light Fixture
One 8" Fixture...............................................................1.1A
One 4' Fixture ................................................................0.6A
Fan (each) ....................................................................1.9A
Electronic System (V-Room Practice only) ..................1.0A @ 120V AC 60 Hz
Inrush Current ...............................................................20A maximum for 2 milliseconds.
Time to Steady State ....................................................10 milliseconds.
Interior outlets, maximum amperage per power panel available is 10 amps.
C. Floor Load Capacity
Distributed Load ...........................................................200 lb./sq.ft.
Concentrated Load .......................................................300 lb./sq.ft.
D. Glass Specs: (CPSC Standard No. 1201 Category II) Covered by Federal Spec. DD-G-451C
Inner Pane: 3/16"x24 15/16"x76 7/8" Laminated Safety Glass with .030 Plastic.
Outer Pane: 1/4"x24 15/16"x76 7/8" Laminated Safety Glass with .030 Plastic.