background image

Read the manual thoroughly.

Improper installation, operation or
maintenance can cause property
damage, injury or death. 

!

SteamCraft 

Gas Convect

i

on Steamer

November 2019    

Part  #  -  KE004036-2

  D

Operation, 

Installation & Maintenance

 Manual

This manual is updated as new information and models are released. Visit our website for the latest manual.

MODEL

:

24CGA10

For your future reference.

Model # ______________________________________

Serial # _______________________________________

Visit www.clevelandrange.com to locate a 
service or sales representative in your area.

Содержание CLEVELAND SteamCraft 24CGA10

Страница 1: ...036 2 D Operation Installation Maintenance Manual This manual is updated as new information and models are released Visit our website for the latest manual MODEL 24CGA10 For your future reference Mode...

Страница 2: ...nformer aux mesures de s curit normalis es de l industrie y compris mais sans s y limiter les r glementations de l OSHA les proc dures de d branchement verrouillage tiquetage relatives tous les servic...

Страница 3: ...juste modificaci n servicio o mantenimiento puede ocasionar da os a la propiedad lesiones o muerte Lea detenidamente las instrucciones de instalacion y de operaci n antes de instalar poner a funcionar...

Страница 4: ...de presi n Keep clear of pressure relief discharge Restez l cart de la soupape de suret Permanezca alejado de la descarga de presi n Do not lean on or place objects on the equipment Ne vous penchez p...

Страница 5: ...erence Lighting and Shutdown Summary Instructions 5 B Control Panel Switches 6 C Operating and Cooking Procedure 7 D Timed Mode Operating and Cooking Procedure 7 E Manual Mode Operating and Cooking Pr...

Страница 6: ...st for Dial Timer Control Panel 24 E Timer Test for Keypad Control Panel 25 F General Information about the Compartment Door Optional Steam Cut Off Switch 25 G Function Test for the Compartment Door O...

Страница 7: ...precautions in addition to the posted instructions Do not light or start any appliance Do not touch any electrical switch Do not use any phone in the building Immediately call the gas supplier from a...

Страница 8: ...qualified Cleveland Range authorized service representative BURN and SCALD HAZARD Exposure to steam condensate and hot surfaces can cause death burns and scalds To help avoid injury Do NOT breathe st...

Страница 9: ...orized service representative Model Number____________________________________________________________ Write the Model Number of your appliance here Serial Number______________________________________...

Страница 10: ...ompartment door and reduced cooking performance To help avoid injury When checking inside the cooking compartment always stand to the hinge side and away from the appliance and open the door slowly In...

Страница 11: ...n about 6 minutes 4 Turn ON one or both cooking compartments ON OFF controls Turn ON Dial Timer Set to Manual Mode OR set a time in Timed Mode Keypad Timer Set a time and press the START STOP key 5 Th...

Страница 12: ...ER ON and GENERATOR FILL Switch with Power On Indicator Light This is the ON OFF switch Turn this switch ON to power the control panel and fill the steam generator B CONTROL PANEL SWITCHES Figure 4 1...

Страница 13: ...ut door to maintain cooking compartment temperature b If another use is not planned for more than half an hour leave the cooking compartment door open slightly c If the appliance will not be used agai...

Страница 14: ...the knob clockwise until it points to the required time When the Timer reaches 0 a buzzer sounds for 3 seconds The Dial Timer does NOT work in Manual Mode 2 TIMED MANUAL Switch The TIMED MANUAL switch...

Страница 15: ...imer must be reset to zero 00 00 zeroed by pressing this key before a new time can be set 4 START STOP Key Press this key to start and stop the Timer Press and hold for 5 seconds to stop functions In...

Страница 16: ...ust be performed at the end of each shift 3 Blowdown Procedure a Follow the Shut Down instructions in Chapter 4 b EITHER restart the appliance by following Lighting instructions in Chapter 4 OR if the...

Страница 17: ...from the door b Wipe the gasket assembly with a damp cloth c Wipe the inside of the door with a damp cloth d Rotate the gasket assembly 180 This makes the gasket last longer e Replace the gasket assem...

Страница 18: ...s c Position the appliance so it will not tip or slide d The operating surface must be level enough to allow leveling with the adjustable legs This appliance MUST be level both front to back and side...

Страница 19: ...th all local state and national codes for venting gas fired appliances b The exhaust hood must be sized for the cumulative ventilation requirements of all the gas fired appliances in the area under th...

Страница 20: ...Installer Owner is responsible for furnishing and installing gas supply lines valves regulators and accessories When installing gas supply lines and accessories observe the following a Refer to Figur...

Страница 21: ...Requirements a Contact Cleveland Range for details on how to provide water per Minimum Water Quality Requirements in the Warranty or how to increase the frequency of maintenance cleaning and descalin...

Страница 22: ...rements shown in the Warranty then use the Separate Feed Water Supply Arrangement shown in Figure 3 4 Figure 3 3 Cleveland Range Single Water Supply Arrangement Figure 3 4 Cleveland Range Separate Wat...

Страница 23: ...the Condensate Drip Trough The connection must be made as follows 1 Install a main disconnect switch and a separate fuse or breaker for this appliance as shown in Figure 3 9 The fused disconnect swit...

Страница 24: ...n to any drain material that cannot sustain 180o F 6 Do NOT connect any other drain from any other equipment to the drain line of this appliance 7 Do NOT connect the drain outlet extension line direct...

Страница 25: ...ric Power Requirements Met Rating Plate Ch 7 Gas Supply Requirements Met Rating Plate Ch 7 Exhaust Hood Requirements Met Ch 7 See spec sheet Installation Ch 7 Check Level Front to Back and Side to Sid...

Страница 26: ...de at the end of this manual Burner Ignition Test Lighting and Shutdown Instructions NOTE Perform this test before Startup Test Procedure NOTE For new installations or when air in gas lines is suspect...

Страница 27: ...conds as long as the steamer is ON and has water in it and the cooking compartments are off or the appliance is in Timed mode with the Timers at 0 Do not work near or above the exhaust flue whenever p...

Страница 28: ...rform the test procedure for the type of control panel on the appliance being installed A Startup Procedure with the Appliance De Energized 1 Start with or the Main External Power Switch OFF 2 Check t...

Страница 29: ...t 11 After the 3 minute blowdown cycle ends no water flows into the float column or out of the drainpipe 12 Go to C Operating Test Procedures C Operating Test Procedures 1 Turn OFF the Main External P...

Страница 30: ...ero Note The buzzer will NOT sound in Manual Mode 3 Set the TIMED MANUAL switch to TIMED a The buzzer sounds for 3 seconds b Steaming stops c Condenser flow stops 4 Open the cooking compartment doors...

Страница 31: ...eys 1 0 0 0 b The display reads 10 00 ten minutes and zero seconds 6 Press the START STOP key The timer reads PAUS pause The cooking compartments begin to heat 7 The timer reads PAUS pause until cooki...

Страница 32: ...8 If steaming does not start Shut down the appliance and call your qualified Cleveland Range authorized service representative 9 Repeat this test with the lower cooking compartment door 10 Repeat this...

Страница 33: ...the instructions of the drain cleaner manufacturer Flush the cooking compartments and drains with clean water E Monthly Maintenance 1 Descale the Steam Generator Steam Generators should be descaled o...

Страница 34: ...lve containers and Material Safety Data Sheets supersede and replace instructions and warnings in this manual DANGER The liquid solution in Cleveland Range Descaler Solution Part No 106174 or 1061741...

Страница 35: ...descaling solution enters cooking compartment s through steam nozzles Note Some descaling solution will flow from drain of Ultra 10 gas steamers Adding extra water to generator s raises descaling sol...

Страница 36: ...find out how often it must be cleaned a Close the valve s in the water supply line s b Unscrew the filter cap from the bottom of the strainer c Remove the filter screen and wash it with clean water d...

Страница 37: ...ater supply to steamer shut OFF Open water supply valves Door interlock switch not engaged or has failed if unit has this option Close door completely If problem persists see Note 1 Water line straine...

Страница 38: ...ut of steam ports into cooking compartment See Warning under Note 9 Water probes are dirty Turn OFF water supply to steamer and descale steamer manually with Cleveland Range approved descaler See Oper...

Страница 39: ...Cleveland Range Please have the model number and serial number ready when calling Cleveland Range will not pay for warranty repairs by unauthorized maintenance and repair centers 2 Proper installation...

Страница 40: ...eded Failure to follow these precautions can cause burns scalds and equipment damage EGG SIZE CHART Egg Size SteamCraft Steamer Medium 10 minutes Large 12 minutes Extra Large 12 minutes 3 When time is...

Страница 41: ...itchencare com To learn how Welbilt Foodservice and its leading brands can equip you visit our global web site at www welbilt com then discover the regional or local resources available to you Every n...