7 Segment Display is flashing
The display flashes in the following conditions:
Trying to change a parameter value when it is not allowed;
Soft-Starter in Fault condition (see table 8.1).
All Soft-Starter settings are made through the parameters. The para-
meters are shown on the display with the letter
P
followed by a number:
Example (P101):
4.2.3 Parameter viewing and pro-
gramming
Init. Volt Start
P101=30%
101= Parameter Number
Each parameter is associated with a numerical value (parameter
content), that corresponds to an option selected among the options
available for this parameter.
The values of the parameters define the Soft-Starter programming or
the value of a variable (e.g. current, frequency, voltage). For Soft-S-
tarter programming you should change the parameter(s) content(s).
Press the key
Use the keys and
ACTION
LED DISPLAY
DESCRIPTION
LCD DISPLAY
SoftStarter
Ready
Motor Current
P002=0.0%
Init. Volt Start
P101=30%
Select the desired parameter
Alarm description
Soft-Starter with Alarm
Note:
These states are showed automatically on the dis-
play; the others are in the parameter P006. Refer to the
chapter 6.