![WEG SSW06 Скачать руководство пользователя страница 61](http://html.mh-extra.com/html/weg/ssw06/ssw06_user-manual_950614061.webp)
CHAPTER 3 - INSTALLATION AND CONNECTION
61
3.3.1 Recommended Set-up using Keypad Command with Isolating Contactor
Figure 3.22
- Recommended Set-up using Keypad command with isolating contactor
See notes in the item 3.3
+ t
o
M
3~
PTC
R
S
T
PE
K1
R S T
1 2 PE
33 34
X1E
X1A
18
19
RL1
RL2
20
21 22 23 24
RL3
X1C
X1B
Dl1
3
Dl2
4
Dl3
5
Dl4
6
Dl5
7
COM
8 9
0V
10
24V
11
PTC
B A
12 13
U V W
Fault
T1
K1
P279 =6
P277 =1
P229 =0
P220 =0
3.3.2 Recommended Set-up using Keypad Command with Circuit-breaker
Figure 3.23
- Recommended Set-up using Keypad command with circuit-breaker
See notes in the item 3.3
R
S
T
PE
Q1
R S T
1 2 PE
33 34
X1E
X1A
18
19
RL1
RL2
20
21 22 23 24
RL3
X1C
X1B
Dl1
3
Dl2
4
Dl3
5
Dl4
6
Dl5
7
COM
8 9
0V
10
24V
11
PTC
B A
12 13
U V W
Fault
T1
Q1
Circuit-bre-
aker with
under voltage
release
Q2
+ t
o
M
3~
PTC
P279 =7
P229 =0
P220 =0