SSW-06 - QUICK PARAMETER REFERENCE
II. Fault or Alarm Messages
Display
Description
Page
E03
Undervoltage, Phase Fault or Phase
160
Unbalancing
E04
Overtemperature at the Power Assembly
160
E05 or A05
Motor Overload
160
E06 or A06
External Fault or Alarm (DI)
160
E10
Copy Function Fault
160
E11
Ground Fault
161
E15
Motor is not Connected or SCRs in Short-circuit
161
E16 or A16
Overvoltage
161
E18
Wrong Motor Connection
161
E19
Short Circuit in the SSW Power
161
E24
Programming Error
161
E28
Timeout Error in the Telegram Reception
161
E29
Inactive Fieldbus communication or Profibus
161
master in Stop Fault
E30
Fieldbus Board is Inactive
161
E31
Keypad Connection Fault
161
E32 or A32
Motor Overtemperature (DI)
162
E33 or A33
Motor Overtemperature Ch1
162
E34 or A34
Motor Overtemperature Ch2
162
E35 or A35
Motor Overtemperature Ch3
162
E36 or A36
Motor Overtemperature Ch4
162
E37 or A37
Motor Overtemperature Ch5
162
E39
Without Optional PT106 Card
162
E41
Self-Diagnosis Fault
162
E43 or A43
Ch1 Motor Temperature Broken Cable
162
E44 or A44
Ch2 Motor Temperature
Broken Cable
162
E45 or A45
Ch3 Motor Temperature
Broken Cable
162
E46 or A46
Ch4 Motor Temperature
Broken Cable
162
E47 or A47
Ch5 Motor Temperature
Broken Cable
162
E48 or A48
Ch1 Motor Temperature
Short Circuit
163
E49 or A49
Ch2 Motor Temperature
Short Circuit
163
E50 or A50
Ch3 Motor Temperature
Short Circuit
163
E51 or A51
Ch4 Motor Temperature
Short Circuit
163
E52 or A52
Ch5 Motor Temperature
Short Circuit
163
E57
Failure in SCR R-U
163
E58
Failure in SCR S-V
163
E59
Failure in SCR T-W
163
E62
Start Limiting Time
163
E63
Locked Rotor
163
E65 or A65
Undercurrent
163
E66 or A66
Overcurrent
163
E67
Inverted Phase Sequence
163
E70
Undervoltage at the Electronics
164
E71
By-pass Contact is Open
164
E72
Overcurrent before By-pass Contact
164
E74
Current Imbalance
164
E75
Frequency of Supply Line out of Permitted Range
164
E76
Undercurrent before By-pass
164
E77
By-pass Contact is closed or SCRs in Short-circuit
164
E78 or A78
Undertorque
164
E79 or A79
Overtorque
164
E80 or A80
Underpower
164
E81 or A81
Overpower
165
E85
Without SoftPLC
165
E86 to E89
SoftPLC user errors
165
A90 to A93
SoftPLC user alarms
165
III. Other Messages
For more details see table 8.1 in chapter 8.
Display
Description
rdy
Soft-Starter is ready to be enabled
Exx
Soft-Starter fault
Axx
Soft-Starter with alarm