NOTE!
During the inverter operation, the modified parameters are saved in the FLASH memory module
regardless of user's command, when P0318 = 3. This assures that the MMF will always have an
updated copy of the inverter parameters.
NOTE!
When the inverter is powered on and the memory module is present, the current values of its
parameters is overridden if P0318 = 3. If you want to copy from another inverter, set P0318 to 0
before inserting the card.
NOTE!
When the inverter is powered on and the memory module is not detected, P0318 is not visible or
changeable by the user and it is automatically set to 0.