13
Digital and Analog Inputs and Outputs
13-20 | CFW700
(q) F > Fx
(2)
P0281 - P0282
Fx (P0281)
N
OFF
ON
Relay /
Transistor OFF
(r) No Alarm
Relay /
Transistor
ON
No Alarm
OFF
Time
Alarm
Figure 13.6 (q) and (r) (cont.):
Details on the operation of the digital and relay output functions
P0281 – Fx Frequency
Adjustable
Range:
0.0 to 300.0 Hz
Factory
Setting:
4.0 Hz
Properties:
Access groups
via HMI:
Description:
It is used in the digital output and relay functions:
F > Fx
(1)
and F > Fx
(2)
P0282 – Fx Hysteresis
Adjustable
Range:
0.0 to 15.0 Hz
Factory
Setting:
2.0 Hz
Properties:
Access groups
via HMI:
Description:
It is used in the digital output and relay functions:
F > Fx
(1)
and F > Fx
(2)
P0287 – Nx/Ny Hysteresis
Adjustable
Range:
0 to 900 rpm
Factory
Setting:
18 rpm
(15 rpm)
Properties:
Access groups
via HMI:
Description:
It is used in the
N > Nx
and
N < Ny
functions of the digital and relay outputs.