
11
Vector Control
11-22 | CFW700
P0410 – Motor Magnetization Current (I
m
)
Adjustable
Range:
0 to 1.25 x I
nom-ND
Factory
Setting:
I
nom-ND
Properties:
Access groups
via HMI:
MOTOR
Description:
It is the motor magnetization current value.
It can be estimated by the self-tuning routine when P0408=2 (Run for I
m
) or obtained from an internal table
based in standard WEG motors, when P0408=1 (No rotation).
When a standard WEG motor is not used and it is not possible to run the self-tuning with P0408=2 (Run for I
m
),
then adjust P0410 with a value equal to the motor no load current, before initiating the self-tuning.
For P0202=5 (vector mode with encoder), the value P0410 determines the motor flux, therefore it must be
properly adjusted. If it is low, the motor will operate with a reduced flux compared to the rated condition, having,
consequently, its torque capability reduced.
P0411 – Motor Flux Leakage Inductance (
σ
ls)
Adjustable
Range:
0.00 to 99.99 mH
Factory
Setting:
0.00 mH
Properties:
cfg and Vector
Access groups
via HMI:
MOTOR
Description:
It is the value estimated by the self-tuning.
The P0411 setting determines the current regulator proportional gain.
NOTE!
When adjusted via the keypad (HMI), this parameter may change the parameter P0167 automatically.
Содержание CFW700
Страница 2: ......
Страница 4: ......
Страница 8: ...Summary...
Страница 34: ...2 General Information 2 4 CFW700...
Страница 38: ...3 About the CFW700 3 4 CFW700...
Страница 56: ...7 Starting up and Settings 7 4 CFW700...
Страница 58: ...8 Available Control Types 8 2 CFW700...
Страница 78: ...10 VVW Control 10 8 CFW700...
Страница 158: ...13 Digital and Analog Inputs and Outputs 13 28 CFW700...
Страница 184: ...16 Read only Parameters 16 12 CFW700...