VVW Vector Control
10-4 | CFW501
10
Power [P0404]
Frame
Voltage
[P0400]
(V)
Current
[P0401]
(A)
Frequency
[P0403]
(Hz)
Speed
[P0402]
(rpm)
Efficiency
[P0399]
(%)
Power
Factor
[P0407]
Stator
Resistance
[P0409] (Ω)
(CV)
(kW)
0.16
0.12
63
230
0.73
50
1375
57.0
0.72
30.62
0.25
0.18
63
1.05
1360
58.0
0.74
20.31
0.33
0.25
71
1.4
1310
59.0
0.76
14.32
0.50
0.37
71
1.97
1320
62.0
0.76
7.27
0.75
0.55
80
2.48
1410
68.0
0.82
5.78
1.00
0.75
80
3.23
1395
72.0
0.81
4.28
1.50
1.10
90S
4.54
1420
77.0
0.79
2.58
2.00
1.50
90L
5.81
1410
79.0
0.82
1.69
3.00
2.20
100L
8.26
1410
81.5
0.82
0.98
4.00
3.00
100L
11.3
1400
82.6
0.81
0.58
5.00
3.70
112M
14.2
1440
85.0
0.83
0.43
7.50
5.50
132S
19.1
1450
86.0
0.84
0.25
10.0
7.50
132M
25.7
1455
87.0
0.84
0.20
0.16
0.12
63
400
0.42
50
1375
57.0
0.72
91.85
0.25
0.18
63
0.60
1360
58.0
0.74
60.94
0.33
0.25
71
0.80
1310
59.0
0.76
42.96
0.50
0.37
71
1.13
1320
62.0
0.76
21.81
0.75
0.55
80
1.42
1410
68.0
0.82
17.33
1.00
0.75
80
1.86
1395
72.0
0.81
12.85
1.50
1.10
90S
2.61
1420
77.0
0.79
7.73
2.00
1.50
90L
3.34
1410
79.0
0.82
5.06
3.00
2.20
100L
4.75
1410
81.5
0.82
2.95
4.00
3.00
100L
6.47
1400
82.6
0.81
1.75
5.00
3.70
112M
8.18
1440
85.0
0.83
1.29
7.50
5.50
132S
11.0
1450
86.0
0.84
0.76
10.0
7.50
132M
14.8
1455
87.0
0.84
0.61
15.0
11.0
160M
22.1
1455
88.5
0.81
0.35
20.0
15.0
160L
29.1
1460
89.7
0.83
0.24
P0178 – Rated Flux
Adjustable
Range:
0.0 to 150.0 %
Factory
Setting:
100.0 %
Properties:
Access groups
via HMI:
MOTOR
Description:
It defines the desired flux in the motor air gap in percentage (%) of the rated flux. In general, it is not necessary
to modify the value of P0178 of the standard value of 100 %. However, some specific situations may use values
slightly above to increase the torque, or below to reduce the energy consumption.
P0398 – Motor Service Factor
Adjustable
Range:
1.00 to 1.50
Factory
Setting:
1.00
Properties:
cfg
Access groups
via HMI:
MOTOR, STARTUP
Description:
It is the continuous overload capability, i.e., a reserve of power that gives the motor the capability to withstand
working in adverse conditions.
Содержание CFW501 V1.8X
Страница 2: ......
Страница 8: ...Summary...
Страница 34: ...General Information 2 4 CFW501 2...
Страница 38: ...About the CFW501 3 4 CFW501 3...
Страница 42: ...HMI and Basic Programming 4 4 CFW501 4...
Страница 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Страница 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Страница 76: ...Available Motor Control Types 8 4 CFW501 8...
Страница 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Страница 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Страница 148: ...Faults and Alarms 14 12 CFW501 14...