Basic Instructions for Programming and Settings
CFW501 | 5-1
5
5 BASIC INSTRUCTIONS FOR PROGRAMMING AND SETTINGS
5.1 PARAMETER STRUCTURE
Aiming at simplifying the parameterization process, the CFW501 parameters were classified into ten groups which
can be individually selected in the Menu area of the HMI display. When the enter/menu key of the HMI is pressed in
the monitoring mode, you enter the setting mode level 1. In this mode, it is possible to select the desired parameter
group by browsing with the "
" and "
" keys. For further details on the use of the HMI, refer to
AND BASIC PROGRAMMING on page 4-1
NOTE!
The inverter comes from the factory with the frequency (V/f 50/60 Hz mode) and voltage adjusted
according to the market.
The reset to factory default may change the content of the parameters related to frequency as per
P0204. In the detailed description, some parameters have values between brackets, which represents
the default value for operation in 50 Hz; thus the value without brackets is the default for operation
in 60 Hz.
5.2 PARAMETERS SELECTED BY THE HMI MENU
In the first level of the setting mode, select the group to browse the next levels according to the table below.
Table 5.1:
Parameter group accessed by the HMI MENU
Group
Contained Parameters
PARAM
All parameters.
READ
Read only parameters:
P0001, P0002, P0003, P0004, P0005, P0006, P0007, P0009, P0010, P0011, P0012, P0013, P0014, P0015, P0016,
P0017, P0018, P0019, P0020, P0021, P0022, P0023, P0024, P0027, P0029, P0030, P0037, P0042, P0043, P0044,
P0047, P0048, P0049, P0050, P0051, P0052, P0053, P0054, P0055, P0060, P0061, P0062, P0063, P0064, P0065,
P0070, P0071, P0072, P0073, P0074, P0075, P0080, P0081, P0082, P0295, P0296, P0680, P0690.
MODIF
Only parameters whose contents are different from the factory settings.
BASIC
Parameters for simple application: ramps, minimum and maximum speed, maximum current and torque boost:
P0100, P0101, P0133, P0134, P0135, P0136.
MOTOR
Parameter related to the motor data control:
P0135, P0136, P0137, P0138, P0150, P0151, P0152, P0153, P0156, P0157, P0158, P0178, P0297, P0299, P0300,
P0301, P0302, P0398, P0399, P0400, P0401, P0402, P0403, P0404, P0407, P0409.
I/O
Groups related to digital and analog inputs and outputs:
P0012, P0013, P0014, P0015, P0016, P0017, P0018, P0019, P0020, P0021, P0022, P0105, P0220, P0221, P0222,
P0223, P0224, P0225, P0226, P0227, P0228, P0229, P0230, P0231, P0232, P0233, P0234, P0235, P0236, P0237,
P0238, P0239, P0240, P0241, P0242, P0243, P0244, P0245, P0246, P0247, P0248, P0249, P0250, P0251, P0252,
P0253, P0254, P0255, P0256, P0257, P0258, P0259, P0260, P0263, P0264, P0265, P0266, P0267, P0268, P0269,
P0270, P0271, P0275, P0276, P0277, P0278, P0279, P0281, P0282, P0287, P0288, P0289, P0290, P0291, P0292,
P0293, P0294.
NET
Parameter related to the communication networks:
P0308, P0310, P0311, P0312, P0313, P0314, P0316, P0680, P0681, P0682, P0683, P0690, P0695, P0696, P0697,
P0698, P0760, P0761, P0762, P0763, P0764, P0765.
HMI
Parameter to configure the HMI:
P0200, P0205, P0206, P0208, P0209, P0210, P0211, P0212, P0216, P0510, P0511, P0512, P0513, P0516, P0517.
HVAC
Parameter related to the HVAC function:
P0580, P0581, P0582, P0583, P0584 P0585, P0586, P0587, P0588, P0589, P0590, P0591, P1000, P1001, P1002,
P1003, P1010, P1011, P1012, P1013, P1014, P1015, P1016, P1017, P1018, P1019, P1020, P1021, P1022, P1023,
P1024, P1025, P1026, P1027, P1028, P1029, P1030, P1031, P1032, P1033, P1034, P1035, P1036, P1037, P1038,
P1039, P1040, P1041, P1042, P1043, P1044, P1045, P1046, P1047, P1048, P1049, P1050, P1051, P1052, P1053,
P1054, P1055, P1056, P1057, P1058, P1059, P1060, P1061, P1062, P1063, P1064, P1065, P1066, P1067, P1068,
P1069, P1070, P1071, P1072, P1073, P1074, P1075, P1076, P1077, P1078, P1079.
STARTUP
Parameter to enter the V V W - oriented Start-up mode:
P0202, P0398, P0399, P0400, P0401, P0402, P0403, P0404, P0407, P0408, P0409.
Содержание CFW501 V1.8X
Страница 2: ......
Страница 8: ...Summary...
Страница 34: ...General Information 2 4 CFW501 2...
Страница 38: ...About the CFW501 3 4 CFW501 3...
Страница 42: ...HMI and Basic Programming 4 4 CFW501 4...
Страница 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Страница 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Страница 76: ...Available Motor Control Types 8 4 CFW501 8...
Страница 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Страница 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Страница 148: ...Faults and Alarms 14 12 CFW501 14...