Basic Instructions for Programming and Settings
CFW501 | 5-3
5
P0200 – Password
Adjustable
Range:
0 = Inactive
1 = Active
1 to 9999 = New Password
Factory
Setting:
0 = Inactive
Properties:
Access groups
via HMI:
HMI
Description:
It allows activating the password (by inserting a new value) or disabling it. For further details regarding the use
of this parameter, refer to
Table 5.2: Required procedure for each kind of action on page 5-3
.
Table 5.2:
Required procedure for each kind of action
Action
Procedure
Activate password
1. Set P0200 with the desired value for the password (P0200 = password);
2. After this procedure, the new password is active and P0200 is automatically adjusted for 1 (password
active)
(1)
.
Change password
1. Set the current value of the password (P0000 = password);
2. Set the desired value for the new password in P0200 (P0200 = new password);
3. After this procedure, the new password is active and P0200 is automatically adjusted for 1 (password
active)
(1)
.
Disable password
1. Set the current value of the password (P0000 = password);
2. Set inactive password (P0200 = 0);
3. After this procedure, the password is disabled
(2)
.
Disable password
1. Activate a factory default by means of P0204;
2. After this procedure, the password is disabled
(2)
.
Notes:
(1)
It only allows changing the content of the parameters when P0000 is equal to the value of the password.
(2)
It is allowed to change the content of the parameters and P0000 is inaccessible.
P0205 – Main Display Parameter Selection
P0206 – Secondary Display Parameter Selection
Adjustable
Range:
0 to 1079
Factory
Setting:
P0205 = 2
P0206 = 1
Properties:
Access groups
via HMI:
HMI
Description:
These parameters define which parameters are shown on the HMI display in the monitoring mode.
More details of this programming can be found in
section 5.6 SETTING OF DISPLAY INDICATIONS IN THE
.
Содержание CFW501 V1.8X
Страница 2: ......
Страница 8: ...Summary...
Страница 34: ...General Information 2 4 CFW501 2...
Страница 38: ...About the CFW501 3 4 CFW501 3...
Страница 42: ...HMI and Basic Programming 4 4 CFW501 4...
Страница 58: ...Identification of the Inverter Model and Accessories 6 4 CFW501 6...
Страница 72: ...Logical Command and Speed Reference 7 14 CFW501 7...
Страница 76: ...Available Motor Control Types 8 4 CFW501 8...
Страница 108: ...Functions Common to all the Control Modes 11 14 CFW501 11...
Страница 134: ...Digital and Analog Inputs and Outputs 12 26 CFW501 12...
Страница 148: ...Faults and Alarms 14 12 CFW501 14...