Publication Number 53719. Issue 3, April 2012
SERVICE MANUAL FOR THE 13754 TGX150 INTERNAL RLAN TYPE A/B SC ETM
Page 57
7.5
THE MODULE HOUSING ASSEMBLY
The module housing assembly mounts onto the control board in the lower cover. The
underside of the housing has a transparent window that is aligned with the infra red power
electronics on the control board. This provides power to the module when it is inserted into
the housing; hence the housing contains no electronics. The module housing assembly
provides a means of latching in place modules that have been inserted. The module can be
released by pressing the button on the front (or if solenoid locked by pressing a designated
key on the keyboard to activate the solenoid to release the module).
Figure 24. Module Housing Assembly to Control Board Fixings
MODULE HOUSING
ASSEMBLY
MODULE RELEASE
BUTTON
LOWER COVER
MEMORY EXPANSION &
INTERNAL SERIAL PCB
(Fits directly onto control
board)
TYPE A/B COUPLER
MFRC531
PCB
CONTROL BOARD
MODULE HOUSING
ASSEMBLY
FIXING SCREWS
(3 OFF)
MODULE HOUSING
ASSEMBLY
(SOLENOID
LOCKING
IF FITTED)