4
INSTALLATION
The following information assumes that the ETM is to be fitted in a mounting tray (14262
power, GPS and Serial number) supplied by Wayfarer Transit Systems or their agents.
Paragraph 4.1 gives the installation details, and technical data that may assist in the fitting of the
unit, is given in Section 2 of this manual.
Each mounting tray is fitted with the necessary power cable assembly. The nominal supplied
length is 5 metres. If the mounting tray 14262 is supplied, it has 5 metres of comms cable
attached, this is for connecting your ETM to ancillary equipment i.e. - GPS. If the supplied cable
length is insufficient, you will have to purchase any additional requirement. The UK suppliers
are detailed in Section 2 of this manual.
4.1
INSTALLING THE TICKET MACHINE
The minimum standard flat area required for fitting the ETM mounting tray is 225mm (wide) x
240mm (deep); this will allow the mounting tray to be completely supported with no overhang.
However, a further depth clearance of 30mm and a width clearance of 30mm will be required to
allow for the electronic ticket machine when it is fitted. A depth clearance of 400mm is
required to allow the top cover of the ticket machine to be hinged open when replacing the
ticket roll. Note that a minimum height clearance of 272mm is required to allow the top cover
of the ETM to be hinged open. The mounting tray MUST be mounted on a flat surface, this is
important for Smart Card capable ETM machines so that Smart Cards placed on the surface of
the reader do not slip off.
It is possible to support the mounting tray on a smaller area (125mm x 125mm MINIMUM)
but this is NOT recommended. This would cause a considerable unsupported overhang that
could result in injury to personnel and/or damage to equipment. Even under these conditions,
a clearance area of 255mm (wide) x 270mm (deep) would still be required for the mounting
tray and electronic ticket machine.
WARNING
WAYFARER
TRANSIT
SYSTEMS
LIMITED
ACCEPT
NO
RESPONSIBILITY FOR ANY INJURY TO PERSONNEL OR DAMAGE
TO EQUIPMENT AS A RESULT OF USING A MOUNTING AREA OF
LESS THAN THE MINIMUM STANDARD DETAILED ABOVE.
As the mounting tray's cable assembly has a clear vertical drop from their associated cleating
points, no clearance area is required behind the mounting tray UNLESS the cables are to be
taken out horizontally. Then a minimum clearance of 30mm behind the tray is suggested if
the cable assemblies are to be bent at right angles when leaving the tray.