Section 9: Controls Startup
L-OMM-0003_A
• 10/8/2021 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
45
of
157
9
CONTROLS STARTUP
Before initiating controls startup, verify that:
1. The unit is installed in a location that meets minimum maintenance clearance requirements.
2. Water, gas, venting, combustion air, electric and drain discharge are connected.
3. The water heater has been successfully calibrated and commissioned.
4. AquaSolve TAC media, both UV bulbs and both filters are installed.
5. The unit is connected to the internet via RJ45 connection.
9.1 Sign In
Upon startup, the “Owner” user is created on the device as the default user. The Edge SC
Controller can be accessed with the preassigned password:
2143.
W A R N I N G
Inform the customer to change this password as soon as possible per Section 9.3
9.2 Download & Install the Latest Firmware
Lync is committed to making the Edge SC Controller a reliable and easy to use front-end to your
Water Heating Solutions. As part of that effort, Lync will be continuously monitoring the
user’s
experience and implementing improvements to the Controller firmware.
It is possible the Controller firmware on the unit may be out of date.
You must update the
firmware to the latest version before using the Edge SC Controller for the first time.
This
will eliminate potential problems and allow Lync Technical Support to better serve you if you need
assistance.
The latest firmware can be found directly through the Controller by accessing
Settings
→
Unit
Software
→
Install Update
. Follow the steps in Section 10.4.7.1.
Certified technicians can download the latest firmware from the Lync Learning Management
System (LMS) website at
, or by contacting your local Lync rep.
9.3 Change Owner PIN on Unit
Upon start up, it is highly recommended to change the PIN for the Owner role at this time.
Click on the sequence as shown in the below figures.