Element
Operation and Maintenance
L-OMM-0003_A
• 10/8/2021 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
123
of
157
Mechanical Specifications
Model
LM8414TM-COM
LM8416TM-COM
Dry Weight
124 lbs / 56 kg
145 lbs / 66 kg
Service Weight
458 lbs / 208 kg
550 lbs / 250 kg
Inlet/Outlet Connection
2” FNPT
2” FNPT
Replacement Media
A
M8414-COM-RM
Replace media every 3 years
B
M8416-COM-RM
Replace media every 3 years
Dimensions (nominal - inches)
Model
LM8414TM-COM
LM8416TM-COM
A
14
16
B
73.1
73.1
Max. Service Flow (gpm) vs. Water Temp. (ºF)
System
40º 45º
50º
55º
60º
65º
70º
LM8414TM
40
44
48
50
50
50
50
L M8416TM
45
51
56
59
63
69
75
Intermittent Duty Systems
LM8414TM-COM
50 gpm at all temperatures
LM8416TM-COM
75 gpm at all temperatures
Max. Flow Rate*
LM8414TM-COM
50 gpm
189 lpm
LM8416TM-COM
75 gpm
284 lpm
*Exceeding maximum flow can reduce effectiveness and void warranty.
Pressure drop at peak flow rate is less than 22 psi.
Pressure drop reading taken with inlet and outlet gauges installed at a common elevation and
80 degree feed water.