Element
Operation and Maintenance
L-OMM-0003_A
• 10/8/2021 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
132
of
157
Figure 87 - Rear Panel with Locations of Panel Screws Highlighted
3. Open the hose connection to drain the filter, UV, and AquaSolve (Figure 88).
4. Remove the clamp on the filter housing (Figure 89) and remove lid.
5. Remove and clean or replace the (5) filter cartridges as needed.
6. Assembly is the same as disassembly.
7. Slowly open the ball valves to refill the line.
Figure 88
Figure 89
16.3 AquaSolve Maintenance
The AquaSolve media needs to be replaced every 3 years or sooner, depending on water
conditions. The Edge SC will inform users based on the defined reminder period as well as
when it is recommended to ensure media is on hand. The media are composed of small pellets
that are best collected by way of a sieve or a rice bag. Do not dispose into the drain, but rather
into a refuse container.