Element
Operation and Maintenance
L-OMM-0003_A
• 10/8/2021 Technical Support • (800) 526-0288 • Mon-Fri, 8 am - 5 pm EST Page
134
of
157
4. Connect drain pipe to AquaSolve ball valve.
5. Vent the AquaSolve tank at the top, center inlet.
6. Open ball valve to drain tank and capture media into a rice bag or sieve for disposal. Open
cold-water inlet for 1 minute to flush potential media into suspension to drain.
7. Close ball valve and cold-water inlet.
AquaSolve Ball Valve
8. Open the rear top hatch. Attach AquaSolve media reservoir to the top of the vent.
9. Refill the unit with AquaSolve media M8414-COM-RM at the vent.
10. Slowly open cold-water inlet and fill to top of the vent. Close the inlet and close the vent.
11. Log media replacement in the Element Edge SC control system.
Rear-Top Hatch and Top Vent