20.4 Power specification and ratings
20.4.1 Alternating Current (AC) models
AC Supply voltage/frequency
~100-240 V 50/60 Hz
overvoltage category
II
Maximum voltage fluctuation
±10 % of nominal voltage
AC Power consumption
190 VA
20.4.2 Direct Current (DC) models
DC (Direct Current)
Supply voltage
12-24 V DC
Power consumption
130 W (12V DC)
180 W (24V DC)
20.4.3 Direct Current (DC) models
20.4.3.1 DC power supply option - input characteristics
DC power supply option - input characteristics
Parameter input supply
Limits
Units
Comment
Minimum Nominal Maximum
Operating limits at cable ring terminals 10.4
32.0
V DC
At full
discharge
/charge
Maximum rated input current
15.2
A
At 10.5V/130W
Maximum rated input current
9.5
A
At 24V/200W
Inrush current
17
A
No Load
Inrush current duration
20
mS
Efficiency @ ring terminals
87
91
95
%
100W@10/12/24V
Typical qdos pump power required
5
120
W
qdos 20, 30, 60, 120, CWT
Maximum rated input power
200
W
qdos 20, 30, 60, 120, CWT
20 PRODUCT SPECIFICATION AND EQUIPMENT RATINGS
221
Содержание qdos 20
Страница 40: ...6 Storage 6 1 Storage conditions 41 6 2 Shelf life 41 6 STORAGE 40...
Страница 169: ...Procedure 9 NEXT 10 Use keys to set Alert Level Procedure 11 SELECT to return to FLUID LEVEL SETTINGS 16 OPERATION 169...
Страница 192: ...NOTICE The pumphead locking lever is designed to be loosened or tightened by hand 17 MAINTENANCE 192...